background image

© 2015 All rights reserved. Pg 2

  WARNING - 

Pump only clear water. 

Do not pump fl ammable or explosive fl uids such 
as gasoline, fuel oil, kerosene, etc. Do not use in a 
fl ammable and/or explosive atmosphere. Personal 
injury and/or property damage could result.
NOTE: This pump is not designed to handle 
salt water, brine, laundry discharge or any other 
application which may contain caustic chemicals 
and/or foreign materials. Pump damage could occur 
if used in these applications and will void warranty.

  WARNING - 

All wiring must be 

performed by a qualifi ed electrician. The pump must 
be installed in compliance with all local and national 
codes.

2.  Connect this product to a grounded circuit 

equipped with a ground fault circuit interruptor 
(GFCI) device.

3.  Before installing this product, have the electrical 

circuit checked by an electrician to ensure proper 
grounding.

4.  BE CERTAIN the pump power source is 

disconnected before installing or servicing pump.

5.  Be sure the water source and piping are clear of 

sand, dirt and scale. Debris will clog pump and 
void warranty.

6.  Failure to protect pump and piping from freezing 

could cause severe damage and will void the 
warranty.

7.  Do not run pump dry.

Installation
PUMPING FROM LAKES, PONDS OR 

SMALL STREAMS

1.  Locate pump as close as possible to the water 

source, keeping the vertical distance from the 
water to pump as small as possible. Place pump 
on level support. Protect against fl ooding and 
excessive moisture.

2.  Long lengths of pipe or hose and use of many 

fi ttings will reduce pump fl ow. Use the smallest 
number of fi ttings and shortest possible length of 
pipe or hose.

3.  Connect inlet pipe or hose to pump. The inlet 

connection is designed for 1” NPT thread. Rigid 
pipe such as PVC will work fi ne for inlet and outlet 
pipe. (Reminder: Minimize length of pipe and 
number of fi ttings.) An adapter for garden hose is 
included (see Figure 1).

IL1857

Pump Inlet

Pump Outlet

Figure 1

NOTE: The inlet hose must be a reinforced type 
when pumping from lakes, ponds, or small streams. 
Regular garden hose will collapse and lead to pump 
failure.

4.  A foot valve with strainer should be used to 

maintain prime during operation.

5.  Seal all connections in the inlet hose. An air leak 

in the fi ttings, hose, pipe or connections will draw 
air even though no water leaks out. These inlet 
leaks will reduce pump performance and lead to 
pump failure.

6.  Connect outlet pipe or hose to pump. The outlet 

connection is designed for 1” NPT thread. Rigid 
pipe such as PVC or garden hose may be used. 
An adapter to garden hose thread is included 
(Figure 1).

BOOSTING WATER PRESSURE

  CAUTION - 

Never run the pump dry. 

Running pump without water will cause seal failure. 
Fill pump with water before starting.

1.  Remove priming port on pump and fi ll with water. 

Reinstall priming port on pump (see Figure 2). For 
boosting water pressure: Do not remove priming 
port. Turn on water supply.

IL1858

Priming Port

s

Figure 2

  WARNING - 

Risk of electrical shock! 

This pump is supplied with a grounding conductor 
and grounding type attachment plug. Use a 
grounded receptacle to reduce the risk of fatal 
electric shock.

Summary of Contents for 6913867

Page 1: ...ssure Flammable liquids such as gasoline chemicals or corrosive liquids should never be used with this pump Safety Guidelines This manual contains information that is very important to know and understand This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS To help recognize this information observe the following symbols DANGER Danger indicates an imminently hazardous situatio...

Page 2: ...ture 2 Long lengths of pipe or hose and use of many fittings will reduce pump flow Use the smallest number of fittings and shortest possible length of pipe or hose 3 Connect inlet pipe or hose to pump The inlet connection is designed for 1 NPT thread Rigid pipe such as PVC will work fine for inlet and outlet pipe Reminder Minimize length of pipe and number of fittings An adapter for garden hose is ...

Page 3: ...defective equipment parts or components Damage due to conditions beyond the control of the manufacturer is not covered by this warranty THIS WARRANTY WILL NOT APPLY a To defects or malfunctions resulting from failure to properly install operate or maintain the unit in accordance with printed instructions provided b to failures resulting from abuse accident or negligence or use of inappropriate che...

Page 4: ...nstallation did not pick up prime through a Improper priming b Air leaks c Leaking foot valve 2 Pump has lost prime through a Air leaks b Water level below suction of pump 3 Impeller is plugged 4 Check valve or foot valve is stuck in closed position 5 Pipes are frozen 6 Foot valve and or strainer are buried in sand or mud New Installation a Re prime according to instructions b Check all connection...

Reviews: