Troubleshooting Chart
Symptom

Possible Cause(s)

Corrective Action

Motor will not run

1.  Disconnect switch is off
2.  Fuse is blown
3.  Starting switch is defective
4.   Wires at motor are loose, 

disconnected or wired incorrectly.

1.  Be sure switch is on
2.  Replace fuse
3.  Replace starting switch
4.   Refer to wiring instructions. Check and 

tighten all wiring.

Capacitor voltage may be hazardous. To 
discharge capacitor, touch short capacitor 
terminals with an insulated screwdriver. BE 
SURE to hold handle of screwdriver while 
making contact with capacitor terminals.

Motor runs hot and 
overload kicks off

1.  Motor is wired incorrectly
2.  Voltage is too low
3.  Pump house not properly vented

1.  Refer to wiring instructions
2.   Check with power company. Install heavier 

wiring if wire size is too small (See Wiring 
Chart).

3.  Be sure pump has sufficient ventilation to cool 

the motor

Motor runs but no 
water is delivered. 
NOTE: Check prime 
before looking 
for other causes. 
Unscrew priming plug 
and see if water is in 
priming hole.

1.   Pump in new installation did not pick 

up prime through:

  a.  Improper priming
  b.  Air leaks
  c.  Leaking foot valve
2.  Pump has lost prime through:
  a.  Air leaks

  b.   Water level below suction of pump

3.  Impeller is plugged
4.   Check valve or foot valve is stuck in 

closed position

5.  Pipes are frozen
6.   Foot valve and/or strainer are buried in 

sand or mud

New Installation:

  a.  Re-prime according to instructions
  b.  Check all connections on suction line
  c.  Replace foot valve
2.  Existing Installations:
  a.   Check all connections on suction line and 

shaft seal

  b.   Lower suction line into water and re-prime. 

If receding water level in well exceeds 
suction lift, a deep well pump is needed

3.  Clean impeller
4.  Replace check valve or foot valve
5.   Thaw pipes. Bury pipe below frost line. Heat 

pit or pump house

6.   Raise foot valve and/or strainer above well 

bottom

Pump does not 
deliver water to full 
capacity

1.   Water level in well is lower than 

estimated

1.   A deep well jet pump may be needed (over 

25 ft. (7.6M) to water)

2.   Steel piping (if used) is corroded or 

limed, causing excess friction

2.   Replace with plastic pipe where possible, 

otherwise with new steel pipe

3.  Piping is too small in size

3.  Use larger piping

Replacement Parts

P/N

Description

024609

Impeller, Diffuser, Nozzle Kit

024610

Pump body

Summary of Contents for 6913867

Page 1: ...ssure Flammable liquids such as gasoline chemicals or corrosive liquids should never be used with this pump Safety Guidelines This manual contains information that is very important to know and understand This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS To help recognize this information observe the following symbols DANGER Danger indicates an imminently hazardous situatio...

Page 2: ...ture 2 Long lengths of pipe or hose and use of many fittings will reduce pump flow Use the smallest number of fittings and shortest possible length of pipe or hose 3 Connect inlet pipe or hose to pump The inlet connection is designed for 1 NPT thread Rigid pipe such as PVC will work fine for inlet and outlet pipe Reminder Minimize length of pipe and number of fittings An adapter for garden hose is ...

Page 3: ...defective equipment parts or components Damage due to conditions beyond the control of the manufacturer is not covered by this warranty THIS WARRANTY WILL NOT APPLY a To defects or malfunctions resulting from failure to properly install operate or maintain the unit in accordance with printed instructions provided b to failures resulting from abuse accident or negligence or use of inappropriate che...

Page 4: ...nstallation did not pick up prime through a Improper priming b Air leaks c Leaking foot valve 2 Pump has lost prime through a Air leaks b Water level below suction of pump 3 Impeller is plugged 4 Check valve or foot valve is stuck in closed position 5 Pipes are frozen 6 Foot valve and or strainer are buried in sand or mud New Installation a Re prime according to instructions b Check all connection...

Reviews: