background image

SKU: 691-1615 

UNIVERSAL TETHERED FLOAT SWITCH 

Risk of electrical shock.  Can burn or kill.  To reduce risk of electrical shock, disconnect the power supply before replacing switch.  Make 

sure switch is connected only to a properly grounded grounding type receptacle.

 

Short  circuit  electrical  hazard.    An  incorrect  connection  may  cause  electric  shock,  or  burn  out  the  pump  motor,  resulting  in  property 

damage or personal injury.  Make sure all connections are correct before plugging the switch into the outlet. 

 

The  outlet  voltage  and  pump  voltage  must  match.    Ensure  voltage  is  correct  before  installing  switch.  The  electrical  outlet  must  be 

installed outside the pump basin. 

 

Risk of flooding. It is recommended to operate the pump through two or three complete cycles to ensure proper liquid level control.

 

Installation and Operating Instructions

 

1.  Determine the required tether length/pumping range for your 

installation  using  the  dimensions  in  the  Tether  Length  Chart.  
Refer to Figure 2.  

2.  Attach the float switch cable to the pump discharge pipe using 

the  plastic  mounting  clamp  and  stainless  hose  clamp  (see 
Figure 1).  NOTE: Do not install the cord under the hose clamp.   

3.  Locate the clamp at the desired activation level and secure to 

the discharge pipe.  

4.  Make  sure  the  float  operates  freely  without  contacting  the 

sides of the basin. 

5.  Secure remaining cord to the discharge pipe to avoid possible 

obstruction with the float switch operation. 

6.  Plug  the  piggyback  plug  of  the  float  switch    into  a  grounded 

outlet,  then  plug  the  pump  into  the  piggyback  plug.  Refer  to 
Figure 3. 

7.  Check for proper operation by filling the basin with water and 

observing  the  float  switch  through  at  least  two  complete 
cycles.    Make  sure  the  pump  operates  at  the  desired  levels.  
Make any necessary adjustments at this time. 

Installation & Operating Instructions For 

 

Barracuda Brand Pumps

 

1.  Remove the old float switch from the pump by removing the screw and 

cord clamp. 

2.  Determine  the  required  tether  length/pumping  range  for  your  installation 

following the dimensions in the Tether Length Chart or measure the tether 
length from the old switch.  

3.  Attach the stainless steel cord clamp to the new float switch cord at the 

desired tether length. 

4.  Attach clamp to the pump using the appropriate  screw & washer.  Refer to 

Figure 4. 

5.  Plug  the  piggyback  plug  of  the  float  switch    into  a  grounded  outlet,  then 

plug the pump into the piggyback plug. Refer to Figure 3. 

6.  Check  for  proper  operation  by  filling  the  basin  with  water  and  observing 

the float switch through at least two complete cycles.  Make sure the pump 
operates  at  the  desired  levels.    Make  any  necessary  adjustments  at  this 
time. 

        * Pump Sold Separately  

Attach the float 
switch to the top 
of the pump .  
Before tightening 
adjust tether 
length.  

Pump

 

Sold 

 

Separately

 

Switch

 

Tether Length Chart 

Tether Length 

3.5" 

6" 

9" 

12"  15"  18"  22" 

Pumping Range 

8" 

11"  15"  21"  28"  31"  36" 

Figure 2

 

Figure 3

 

Plug Pump  

in here 

To Outlet 

Figure 1

 

Figure 4

 

Safety Guidelines

 

Washer 

Screw 

Cord Clamp 