Hardware Specifications

Interface

Model F183R

5 x 1 GbE RJ45
2 x 1 GbE SFP Optical Fiber

USB 2.0

1

USB 3.0

1

Serial console

1x DB9 RS232

Data Storage

RAM [GB]

4 or higher

Mass Storage

Type

SSD

Size [GB]

100

Size, Weight, Dimensions

Appliance weight [kg]

1.0

Carton weight with appliance [kg]

N/A

Appliance size: width x depth x height [mm]

78 x 127x 146

Carton size: width x depth x height [mm]

N/A

Form factor

Compact, DIN rail mount

Hardware

Cooling

No fan

Environmental

Noise emission [db/A]

n/a

Operating temperature [°C]

-40 to +75

Storage temperature [°C]

-40 to +85

Operating humidity (non-condensing)

5% to 95%

Magnetic Isolation Protection

1.5 KV built-in

Certifications & Compliance

CE emissions

Yes

CE electrical safety

Yes

FCC emissions

Yes

Summary of Contents for CloudGen F183R

Page 1: ...ce Safety Instructions Power supply is not included in packaging and needs to be ordered separately BNGPSUR1a BNGIPSUR1a To prevent damage connect the DC plug to the appliance before plugging the powe...

Page 2: ...a Storage RAM GB 4 or higher Mass Storage Type SSD Size GB 100 Size Weight Dimensions Appliance weight kg 1 0 Carton weight with appliance kg N A Appliance size width x depth x height mm 78 x 127x 146...

Page 3: ...Therefore the list may not re ect the current hardware con guration of the Barracuda appliance it was delivered with Dual Power Supply Connector and P Fail relay 6 PIN connector F183R appliances are...

Page 4: ...the appliance s operational state by changing colors between green and red and by changing between blinking and steady glowing The tables below show the di erent meanings of the di erent glowing stat...

Page 5: ...halted and may be disconnected or an error occurred preventing the appliance from entering the up state Disc LED YELLOW Blinking Appliance is reading or writing on storage Appliance is accessing the i...

Page 6: ...In order to establish a console connection to the appliance using an RS232 serial cable you need to con gure the serial port on the terminal using the following parameters Parameter Value Baud 19200...

Page 7: ...c No portion of this document may be copied distributed publicized or used for other than internal documentary purposes without the written consent of an o cial representative of Barracuda Networks In...

Reviews: