Rack Installation for Barracuda CloudGen Firewall F800 Revision C and F900 Revision A,B
9 / 11
You will only need to secure two out of these four screw holes for each L-shaped bracket to
mount the outer rail safely. Extra holes are for compensating different mechanical designs.
Mounting the Outer Rails to the Rack
Use the following procedures to mount the outer rails to the rack.
Install the outer rail with the attached bracket to the front rack post by using two countersink
1.
screws and conical washers (C).
Extend and adjust the rear bracket to meet the depth of the rack and secure it to the rack post
2.
with two countersink screws and conical washers (C).
Repeat step 1 and 2 above to install the other rail to the other side of the rack.
3.
You may use a wrench to tighten the nuts and the screws that attach the L-shaped brackets to
4.
each of the rails.
Installing the System to the Rail
Pull out the center rail until the extension safety lock is locked.
1.
Hold the system with its front facing you, lift the chassis and carefully insert the system by
2.