background image

#0-313A-SBA  (6/01) 
Page 12 of 14 pages 
BARRETT CENTRIFUGALS INC. 
1-800-228-6442 

The capture tank is furnished with a pump to transfer the fluid to adjacent containers supplied 
by the customer.  The transfer pump is capable of generating a maximum head of 16 feet.  
The interconnecting piping should be sized as large as practical to minimize friction losses 
and should be positioned in the container so as to avoid back flowing to the tank (siphoning). 
  
The transfer pump will operate automatically when power to the control panel is turned 

on

Please refer to the attached wiring diagram for details on wiring and the float switch control 
logic. Normal operation is for the rising fluid to close the contacts of the float switch that 
activates the pump.  

Do not set the shutoff point of the switch too high or the freeboard 

will be insufficient to handle a full load discharge from the Extractor resulting in tank 
overflow.

 

 
 
 

PREVENTIVE MAINTENANCE

 

1. 

Periodic inspection should be made of the balancing springs and the balancing spring 
supports for breakage and spring tension.  If adjustment is required, proceed as outlined 
below.  

Springs should be replaced as a complete set (4) in the event of any spring 

failure. 

 
2.  On machines equipped with a motor cooling blower, the blower inlet screen must be 

inspected weekly.  If the screen is plugged with dirt remove it and simply clean it with 
compressed air.  

DO NOT ATTEMPT TO CLEAN THE SCREEN WHILE THE BLOWER 

IS RUNNING AS DIRT WILL BE BLOWN INTO THE MOTOR!

  Be sure to reinstall the 

screen after cleaning or replace it if damaged.  This keeps chips and debris out of the 
motor windings. 

 
3.  All fasteners should be periodically checked for tightness. 
 
4.  Regularly inspect the rotating assembly for excessive wear, cracks and broken 

components.  Replace any suspect parts immediately. 

 
5.  Check all of the latches and lid attachments periodically to see that they function properly 

and have not become loose or broken. 

 
6.  Never put feet or hands in the hand holes of the drum while the machine is running. 
 
7.  Always replace guards after repairing or checking the machine. 
 
 
LUBRICATION 
The motor spindle bearings are of the grease sealed type requiring no attention.  The pivot 
seat at the base of the motor should be lubricated with #30 SAE oil through the oil cup that 
can be reached through the opening at the lower right front of the machine drum.  Fill with oil 
to the top of the oil cup and check the oil level weekly. Grease the lid hinge weekly. 
 
 

Summary of Contents for 1101

Page 1: ...sludge Prior to using it on any other application you should contact Barrett Centrifugals Inc to determine if the machine can be used successfully and safely THIS EQUIPMENT MUST BE INSTALLED WIRED OPERATED AND SERVICED BY QUALIFIED PERSONS ONLY READ UNDERSTAND AND COMPLY WITH THESE INSTALLATION OPERATING AND SAFETY INSTRUCTIONS BEFORE INSTALLING OPERATING OR SERVICING THIS EQUIPMENT SAFETY IS ESSE...

Page 2: ...C and possibly a variable speed drive VFD Altering or tampering with the settings that are programmed into these devices could cause the machine to malfunction It could also lead to failure of the safety controls and devices meant to protect personnel and change the motor speed that could severely damage the machine Only qualified personnel should attempt to change the settings Before attempting a...

Page 3: ...through bolts On concrete floors Barrett recommends the use of epoxy set type anchors to secure the machine to the floor The machine must be absolutely solid with the floor Do not set in wet cement Do not run machine without anchoring or vibration may allow it to move about and damage the electrical connections WIRING The wiring of this equipment should be performed by a qualified electrician and ...

Page 4: ...the right hand side of the machine the customer must provide a source of clean dry ambient air piped to enter the blower Failure to comply may allow dry chips being dumped to be sucked into the blower and result in an accumulation of foreign material within the motor ultimately causing premature motor burnout THE ROTATION DETECTOR DC BRAKE The Rotation Detector and DC Brake circuit designed for th...

Page 5: ...t to the PLC If the sequence is verified and completed in the given amount of time a flashing green light indicates that the machine is properly latched and ready to start If the green light does not flash simply retract the lever all the way to the right and start the process over 4 When the START push button is pressed the solenoid pin drops and the green light goes out The pin prevents the latc...

Page 6: ... the weight of a load Do not be tempted to exceed the load sizes noted above They will accommodate most sludge types Remember a pound of sludge will effectively weigh hundreds of pounds under centrifugal force Overloading may cause machine failure and damage to the machine or injury to personnel Do not overload THE 1101 E AND 1101 SES PANS AND COVERS ARE MATCHED SETS AND ARE NOT INTERCHANGEABLE DO...

Page 7: ...anel 10 When the green OPEN signal lights the cycle is complete USE AND CARE OF FILTER ELEMENTS AND SPOKED PAN SES MODEL MACHINE Barrett SES type machines are equipped with special pans and filter elements that maximize the efficiency of the liquid extraction The spokes on the pan create a path for liquid to escape The polypropylene or cotton filter elements retain the sludge in the pan 1 Placemen...

Page 8: ...operating this machine use care to load the pan evenly to insure a good running balance Make sure that all guards and covers are in place 1 Before operating the machine be sure that provisions have been made to capture the extracted liquid from the outlet at the rear of the machine 2 Adjust the cycle timer s 1TRE located within the control panel Barrett recommends an initial setting of 30 minutes ...

Page 9: ...hat it is securely attached Fold the upper half of the side filter which has been draped outside of the pan for sludge loading up and over the load resting it on top of the wet sludge The side filter must be completely within the pan and positioned so it will not be pinched between the pan s top edge and the cover 8 Loading a pan whether empty or full of sludge into the machine will require a hois...

Page 10: ... pan guide tool and spindle of the machine until it comes to rest on the pan support Release the hoist and remove the pan guide tool 13 Attach the spindle nut onto the spindle s threaded top LOCK THE PAN COVER ONTO THE MACHINE S SPINDLE This is extremely important If not done correctly the pan or cover or both may be damaged Other machine components could be damaged or injury to the centrifuge ope...

Page 11: ...r is disconnected the machine will coast to a stop which could take up to 15 minutes OUT OF BALANCE SWITCH OPTIONAL ON SOME MODELS All model 1100 and some 400 machines are equipped with an out of balance switch These switches are located on the underside of the drum s floor In the event of any severe vibration the switch is activated Immediately the cycle in progress is terminated and the machine ...

Page 12: ...ould be replaced as a complete set 4 in the event of any spring failure 2 On machines equipped with a motor cooling blower the blower inlet screen must be inspected weekly If the screen is plugged with dirt remove it and simply clean it with compressed air DO NOT ATTEMPT TO CLEAN THE SCREEN WHILE THE BLOWER IS RUNNING AS DIRT WILL BE BLOWN INTO THE MOTOR Be sure to reinstall the screen after clean...

Page 13: ...E IS RUNNING To plumb the spindle remove tension from the four balancing springs by backing off the jam nuts Plumb the rotating element using a level on top of the flat machined surface of the carrier or pan support Screw the bottom four nuts down until they bear lightly and evenly on all four springs and the carrier registers plumb Tension at this point should be such that the springs can be turn...

Page 14: ...fore any maintenance is performed on the lid latch be sure power is off and locked out To remove the sheet metal guard protecting the latch assembly first remove the front cover of the push button station enclosure Remove the screws holding the guard in place and slide it off of the assembly Clean any contamination or build up from all assembly components use compressed air if available If necessa...

Page 15: ...nd enclosure cover when complete BEARINGS The bearings in this machine are for centrifugal application having special internal fits and should be purchased from Barrett REPAIR PARTS Repair parts are available from Barrett Centrifugals Inc 156 Goddard Memorial Drive Worcester MA 01603 Telephone 800 228 6442 or 508 754 6891 Fax 508 756 5342 E mail sales Barrettinc com Web Site Barrettinc com Be sure...

Reviews: