Selecting Battery Profile
It is very important to set the correct charge profile on the charge controller for
the type of battery installed. Not doing so may result in damage to the battery.
It is recommended to check the set charge profile regardless of whether the
4050 Transporter has been supplied with or without an internal battery.
1.
Welcome Screen - This screen appears every time the charger is powered
on. Two options are presented:
•
Yes - Select if charging a new battery that may need a new profile set.
•
No - Select to use the last charge profile set in the charger. Selecting
this option will immediately begin charging process.
2. The AC-DC charger can charge four types of batteries: 12V lead-acid, Cal
-
cium, GEL or AGM.
• Use the
and
keys to select correct battery type. Press
to confirm.
Note: Refer to the battery label or battery manufacturer if battery type is
unclear. Setting the wrong profile may result in damage to the battery.
•
If Calcium battery is selected, additional confirmation is required as
Calcium batteries charge at a higher voltage than other battery types.
3.
Use the
and
keys to select correct battery size in Ah (Amp
hours). Press
to confirm.
•
If the required Ah rating is not listed, the closest lower rating should
be selected i.e. for a battery size of 105Ah, 100 Amp Hour should be
selected.
These settings will be saved in the charger. Note that only the last profile will be