BH8-Series – User’s Manual
support@barrett.com
www.barrett.com
© 2007 Barrett Technology®, Inc.
Document: D3000, Version: AF.00
Page 55 of 82
Joint 3 Drive Access
Joint 2 Drive Access
Figure 20 - Manual TorqueSwitch™ Activation Drive Holes
Symptom:
Using the GTO or GTC command to open or close the fingers results in the
fingers moving at slightly different velocities. This does not happen with GO
and GC commands.
Possible Solution:
1.
Verify that the finger velocity and filter parameters are the same (MCV, MOV, FPG, FDZ,
FIP, SAMPLE, ACCEL).
2.
Unlike GO and GC commands in which each finger is position controlled to follow a
predefined trapezoidal trajectory that keeps the fingers moving precisely, GTO and GTC
commands apply pure proportional velocity control. Each finger has slightly different friction
due to manufacturing tolerances, resulting in different actual velocities for the same
commanded velocity. Lubricating the high friction fingers will help reduce the friction and
increase the velocity. See Section 7.3 for lubrication instructions. Alternatively, the
commanded gains or commanded velocities from nominal allows you to compensate.
3.
If the problem persists, contact Barrett Technology.