1-716-866-0054
Troubleshooting the Elevating Device
9.
To retest the motor:
Press the K2 button of the tact switches for several times, until 08 shown on
the screen. Then, press the K1 button of the tact switches to confirm the action. The motor will
start to lift.
CAUTION: PINCH POINT!
Do not put fingers near elevating device.
The actuator moves
fast and will not stop until it has moved completely up or completely down.
10.
If the lifting remains smooth, it's fixed. Press the K1 button of the tact switches to stop the
lifting. If not, please re-loosen the 6 screws and repeat the same steps.
3
Troubleshoot the Ball Sensor
Be sure to
REMOVE THE BALL
from inside the table first.
No ball should be on the track or inside the actuator when this test is being administered.
1.
Press K1 button on the PCB. At the same
time, turn on power with other hand.
2.
The screen should show 00.
3.
Press the K2 button of the tact switches
several times, until the screen reads 03.
4.
If all sensors are functioning, four zeros will appear on
the prompt (0000) indicating no sensors need repair.