22 INSTALLATION METHOD
2.
Insert the silicone hose on the hole carefully.
5
.
Fix the silicone hose on the silicone hose guide to let
liquid flow into the water pan.
- Check the silicone hose and the stop-bar, make
sure the part are tighten in the super snow
machine.
4.
Check the silicone hose, make sure insert correctly, adjust the stop-bar and
stop-bar pin hole together.
- Place Stop-bar pin(D) and Mounting bolt for stop-bar(A) on stop-bar
pin hole and push down stop-bar (see figure on the left)
- Tighten the mounting bolt for stop-bar(A) in clockwise.
- Turn clockwise the mounting bolt(C) until silicone hose is pressed
to back disk.
- Turn couter clockwise the interval control disk(B) until tighten between
the silicon hose and disk.
3.
The names and functions of the parts
- I
mportant to know the part during the install and separate the vat from the super snow
machine
A. Mounting bolt for stop-bar - The bolt that holds the stop-bar not to
move.
B. Interval control disk - The disk that is to fix the mounting bolt(C) after
adjust.
C. Mounting bolt - The bolt that adjusts the gap between silicone hose and
stop-bar.
D. Stop-bar pin - The pin that functions as rail to move the stop-bar.
E. Silicon hose - The hose that liquid flows from Vat container.
1.
First of all, push the silicone hose one end connect with
deep pan, and other end insert on the hole.
Make sure the deep pan whole stays in right rear side.
Insert an about half of the protrusions. Makes it difficult to remove
when insert too much.
Silicone hose is a consumable item, so please wash toughly after
use. Change the new hose every month.
VAT (MILK CONTAINER) INSTALLS AND
REMOVES
[Install]
A
B
C
D
E
A
B
C
D
A
B
C
D
Summary of Contents for SUF-200NW-CK