OPERATING SUPER SNOW 25
[
How to Use Super Snow Machine - Condenser
]
To improve the cooling
efficiency...
Please open the back side and both side
of the machine, and clean thoroughly all
over the surface
(reference the photo on
right)
.
The dirt and foreign substance in condenser, causes the deterioration
of freezing function.
The drum will not freeze properly, due to the dust and dirt all over the compressor and motor.
Also cleaning on a regular basis helps prevents the odor and hygiene of product produced in
machine.
Use brush to remove the dirt from
the condenser. Use up-down motion
to remove the dirt.
[
Using related methods
]
Drum is not freezing properly and machine is shutting down during the operation
▶ The cooling fan is not working properly. Let natural cooling down the over-heated
compressor or motor for 30 min
The liquid over flow inside the water bin
▶ The milk (liquid) film might cover the sensor inside.
Sensor located behind the drum.
(
Please wipe down the sensor gently -
check figure on the right - wear latex glove
)
Milk (or liquid) does not coming out
▶ Check the silicone hose – make sure silicon hose
well fit into the valve
Check the silicone hose – make sure silicon hose well fit into the valve
▶ Check the water is turned on the strong regulation. If yes, please lower it down
▶ If the texture of snow flake is like hair, adjust the blade inside the machine and level
of the refrigerant (call Bars Korea for our qualified technician)
▶ If snow comes out in one side, please adjust in horizontal
Drum is freezing during the ‘Clean’ mode
▶ Turn off the power, call Bars Korea service representative for the service
Phenomenon of water on the floor
▶ Check the water hose is removed