background image

Technical data subject to change without notice 

01-3400-7D0001/REV-A-12-2022/ESS-461926

3 / 8

BARTEC Operational Instructions – Control and signal device actuators and accessories

Safety Instructions   

The control and signal device actuators may be used only within 
the specified service and operating temperature. 
Utilisation in areas other than those specified and the 
modification of the product by any one other than the 
manufacturer is not permitted and will exempt BARTEC from 
liability for defects and any further liability . 
Incorrect installation can cause malfunctioning and the loss of 
explosion protection 
Only service technicians who are authorized to work in 
potentially explosive atmospheres may do any of the assembly, 
disassembly, installation, commissioning, maintenance, and 
fault clearance work. 
The generally applicable statutory rules and other binding 
directives relating to workplace safety, accident prevention and 
environmental protection must be observed. 
When setting up or operating explosion-resistant electrical 
systems, IEC/EN 60079-14 and all relevant installation and 
operating regulations must be observed. 
The control and signal device actuators may be used only if it 
is in a clean and undamaged condition. It is not permissible to 
modify the actuators in any way.

Marking  

Particularly important points in these instructions are marked 
with a symbol:

DANGER

  

indicates a hazardous situation which, if not avoided, will 
result in death or serious injury.  

WARNING

  

indicates a hazardous situation which, if not avoided, could 
result in death or serious injury. 

CAUTION  

indicates a hazardous situation which, if not avoided, could 
result in minor or moderate injury.  

NOTICE

  

is used to address practices not related to personal injury. 

NOTE  

Important instructions and information on effective, 
economical and environmentally compatible handling. 

Standards conformed to   

Please see the Attestation of Conformity.  

Transport, Storage  

NOTICE

 

Control and signal device actuators damage through 
incorrect transport or incorrect storage. 

•  Transport and storage is permissible in original packaging 

only.

•  Store the control and signal device actuators in a dry place.

Assembly and Commissioning   

WARNING

 

Risk of injury due to incorrect proceedings. 

•  Only authorized and qualified personnel may do any of the 

assembly, disassembly, installation and commissioning 
work.

•  Use suitable tools.

Assembly/Disassembly

NOTICE

  

Damage to control and signal device actuators due to 
incorrect installation dimensions.

•  The minimum spacing between the mounting holes must be 

observed.

NOTE  

Installation dimensions and assembly drawings, see page 5. 

Commissioning  

Before commissioning, check that: 

 

– The device has been installed correctly.

 

– The device is not damaged.

Installation

The control and signal device actuators must be installed as 
a stationary unit. The following schedule of limitation must be 
observed:

 

– When the components are installed to electrical equipment, 

the service temperature of the components of -55 °C to  
+70 °C  (-67 °F to +158 °F)  must not be exceeded.

 

– The control and signal device actuators, type 07-3400-

A***/**** (push button), and type 07-3400-P***/**** 
(mushroom push button), must only be used in combination 
with the ComEx switch module type 07-332*-****/**** or 
type 07-3382-****/****.

Summary of Contents for 07-3400 Series

Page 1: ...ct to change without notice 01 3400 7D0001 REV A 12 2022 ESS 461926 1 8 BARTEC Operational Instructions Control and signal device actuators and accessories Control and signal device actuators and acce...

Page 2: ...ories The components are developed and certified for global hazardous areas Control and signal device actuators and accessories Type 07 3400 Explosion protection Technical data Notified Body Number 00...

Page 3: ...which if not avoided could result in death or serious injury CAUTION indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices...

Page 4: ...damage Make sure that they are properly established NOTICE Damage to actuators due to incorrect cleaning It is not allowed to clean control and signal device actuators with compressed air The operator...

Page 5: ...8 3 4 Nm 2 2 5 lb ft 5 Torquing tool The control and signal device actuators may optionally be provided with one of the following accessories protective collar locking device shield holder marking cl...

Page 6: ...ition relative to the anti rotation device Marking clip Shield holder Attach the holding frame of the locking device to the application housing from above Note the position relative to the anti rotati...

Page 7: ...nte Stelle Procedure of EU Type Examination Notified Body Proc dure d examen UE de type Organisme Notifi CML 21ATEX31132 U Issue 0 2776 CML B V Hoogoorddreef 15 1101BA Amsterdam NL Die Ex Komponente i...

Page 8: ...ice 01 3400 7D0001 REV A 12 2022 ESS 461926 8 8 BARTEC Operational Instructions Control and signal device actuators and accessories bartec com BARTEC BARTEC GmbH Max Eyth Str 16 97980 Bad Mergentheim...