background image

Technical data subject to change without notice 

01-3400-7D0001/REV-A-12-2022/ESS-461926

4 / 8

BARTEC Operational Instructions – Control and signal device actuators and accessories

 

– To confirm with IEC 60947-5-5 & UL 60947-5-5 the E-stop 

twist and pull to release actuators 07-3400-R***/**** & 
07-3400-N***/****, have to be used in combination with the 
ComEx Modules. (combinations of E-stop twist with 4-pole 
ComEx switch module type 07-3382-* 1xNC/3xNO & 4xNO 
is not allowed. In addition, a yellow background is required, 
which can be created using the BARTEC background sticker 
05-2144-1097 or protective collar 05-0032-0019. 

 

– In the case of the pushbutton type 07-3400-A* and double 

pushbutton 07-3400-C*, it is absoluty necessary to attach an 
enclosed colored label.

Maintenance and Fault Clearance  

WARNING

 

Risk of injury due to incorrect proceedings. 

•  Only authorized qualified personnel may do any of the work 

relating to maintenance and fault clearance.

•  IEC/EN 60079-17 and all relevant installation and operating 

regulations must be observed.

It is recommended to formulate a maintenance plan according 
to standards.

Maintenance  

WARNING

 

Risk of serious accidents due to damaged parts.  

•  Check actuators regularly for cracks and damage. Make 

sure that they are properly established.

NOTICE

 

Damage to actuators due to incorrect cleaning.  

•  It is not allowed to clean control and signal device actuators 

with compressed air.

The operator of the control and signal device actuators must 
keep it in good condition, operate it properly, monitor it and clean 
it regularly. 
The owner/managing operator must schedule maintenance 
intervals which will suit the respective conditions of use. 

Fault Clearance  

WARNING

 

Risk of serious injury due to use of non-original spare parts.   

•  Use original parts only as replacements.

The control and signal device actuators are defective if it no 
longer actuates the attached command equipment or if the 
illuminated disc becomes damaged. Defective actuators cannot 
be repaired. 
Defective control and signal device actuators can be taken 
off and replaced by functioning actuators of the same type 
considering this operational instruction.

Disposal  

NOTE  

Environmental damage can be caused by incorrect waste 
disposal. When in doubt, local authorities or specialist disposal 
companies can provide information on environmentally 
friendly disposal.

The components in the switch module contain metal and plastic 
parts. Therefore the statutory requirements for disposing of 
electronic scrap must be observed.

Service-Address

BARTEC GmbH

Max-Eyth-Str. 16
97980 Bad Mergentheim
Germany

Phone: +49 7931 597-0
info@bartec.com

Summary of Contents for 07-3400 Series

Page 1: ...ct to change without notice 01 3400 7D0001 REV A 12 2022 ESS 461926 1 8 BARTEC Operational Instructions Control and signal device actuators and accessories Control and signal device actuators and acce...

Page 2: ...ories The components are developed and certified for global hazardous areas Control and signal device actuators and accessories Type 07 3400 Explosion protection Technical data Notified Body Number 00...

Page 3: ...which if not avoided could result in death or serious injury CAUTION indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices...

Page 4: ...damage Make sure that they are properly established NOTICE Damage to actuators due to incorrect cleaning It is not allowed to clean control and signal device actuators with compressed air The operator...

Page 5: ...8 3 4 Nm 2 2 5 lb ft 5 Torquing tool The control and signal device actuators may optionally be provided with one of the following accessories protective collar locking device shield holder marking cl...

Page 6: ...ition relative to the anti rotation device Marking clip Shield holder Attach the holding frame of the locking device to the application housing from above Note the position relative to the anti rotati...

Page 7: ...nte Stelle Procedure of EU Type Examination Notified Body Proc dure d examen UE de type Organisme Notifi CML 21ATEX31132 U Issue 0 2776 CML B V Hoogoorddreef 15 1101BA Amsterdam NL Die Ex Komponente i...

Page 8: ...ice 01 3400 7D0001 REV A 12 2022 ESS 461926 8 8 BARTEC Operational Instructions Control and signal device actuators and accessories bartec com BARTEC BARTEC GmbH Max Eyth Str 16 97980 Bad Mergentheim...

Reviews: