background image

Operation

 

Industry Tablet PC 10.1" 

Agile X IS 

 

Type 17-A1B*-****/******** 

 

EN      32/43 

Subject to technical changes. 

05/2017 

 

 

7.3.8

 

Equipping laser devices 

 

Laser warning note 

Notice no. 50 dated June 24th, 2007 and EN60825-1: 2007 and IEC60825-1 (ed. 2.0). 
The laser classification is specified on a sticker attached to the device. 
Class 2 laser scanners use a low-power laser diode with visible light. As is the case 
with any bright light source, such as the sun, always avoid looking directly into the light 
beam. No information is available regarding the potential dangers of being exposed to 
class 2 laser light for a brief period. 
Caution: The use of control elements which change settings or initiate procedures that 
are  not  mentioned  here  can  lead  to  a  situation  in  which  persons  are  exposed  to 
hazardous laser beams. 

 

 

7.3.9

 

LED units 

 

 

CAUTION 

Laser radiation! May damage eyesight! 

 

Do not look into the laser beam. 

 

Devices supplied by BARTEC with LED light comply with the following directive: 

 

EN 60079-28 for LED safety 

 

 

7.3.10

 

Restrictions in the case of wireless devices 

 

 

The  use  of  wireless  devices  is  possibly  forbidden  or  restricted.  This  applies 
primarily on board aircraft, in hospitals, in the vicinity of explosive substances or 
under other hazardous conditions. If you are not sure which regulations apply to 

the use of the device, ask permission before switching it on. 

 

 

Radio modules 

The  device  contains  radio  modules.  The  identification  data  for  these  modules  are 
provided below: 

 

Radio  module  from  BARTEC  which  supports  WLAN  802.11  a/b/g/n/ac  and 
Bluetooth. 

Bluetooth®

 

radio technology

 

This is an authorized Bluetooth® product. Further information and an end product list is 
provided at https://www.bluetooth.org/tpg/listings.cfm

Country-specific roaming 

This device has the International Roaming function (IEEE802.11d) which ensures that 
the device is used on the channels prescribed for the respective country. 

Ad-hoc operation 

The ad-hoc operation is restricted to the channels 36–48 (5150–5250 MHz). The use of 
this bandwidth is restricted to indoor areas; use outdoors is not permitted. 

 
 

Summary of Contents for Agile X IS

Page 1: ...10 1 Industry tablet PC 17 A1B User Manual...

Page 2: ......

Page 3: ...artec de User Manual Translation Industry Tablet PC 10 1 Agile X IS Type 17 A1B ATEX IECEx Zone 0 ATEX IECEx Zone 1 UL Class I Division 1 UL Class I Zone 0 UL Class I Zone 1 Document No 11 A1B0 7D0001...

Page 4: ...plicable documents set of documents 5 1 10 Definition of terms 6 1 11 Configuration 6 2 Product description 7 2 1 Agile X IS 7 2 2 Structure 7 2 2 1 Front side 7 2 2 2 Rear side 8 2 2 3 Side view 9 2...

Page 5: ...ve replace screen protector 29 6 7 Add on module 29 7 Operation 30 7 1 Final inspection 30 7 2 Cleaning 30 7 3 Operation recommendations and requirements 31 7 3 1 Basic safety and health protection re...

Page 6: ...Blank page...

Page 7: ...iance with it is essential for safe installation and commissioning Accidents injuries and material damage can be avoided by circumspect handling and systematically following the instructions The examp...

Page 8: ...nslation or printing In the case of legal disputes the General Terms and Conditions of Business of the BARTEC GmbH also apply The current versions of the datasheets operating instructions certificates...

Page 9: ...ety and accident prevention and who have been inducted in the use of the tablet PC have read and understood the documentation the safety chapter and the warnings The operator checks that the safety an...

Page 10: ...e correct condition 1 6 4 Repairs Repairs to explosion proof equipment may only be performed by persons authorized by BARTEC who must employ the latest technological practices observe the manufacturer...

Page 11: ...nd external rechargeable battery year starting from the BARTEC delivery date The warranty period for accessories is 1 year from the date of delivery This warranty covers all parts of the delivery and...

Page 12: ...r applications are not contained in the delivery Configuration Version Processor Intel Pentium N3710 Quad Core 1 6 GHz Display 10 1 Resolution 1920 x 1200 pixel System memory 8 GB SODIMM DDR3L 1600 Ma...

Page 13: ...d for use in industrial environments and was developed specifically by BARTEC for use in potentially explosive atmospheres 2 2 Structure 2 2 1 Front side No Description 1 Full HD 10 finger multi touch...

Page 14: ...t Micro SIM card slot Charging port 12 Volume 13 Function key 14 Expansion port for add on modules 15 High quality 5MP camera with flash 16 SE4500 1D 2D Imager from Zebra Technologies Corporation opti...

Page 15: ...hin potentially explosive atmospheres The tablet PC Agile X IS is used exclusively in combination with devices which comply with the requirements placed on the overvoltage category I The tablet PC Agi...

Page 16: ...0 C Ta 50 C Test certificate IECEx UL 16 0160 Standards IEC 60079 0 2011 IEC 60079 11 2011 IEC 60079 28 2014 Guidelines ATEX 2014 34 EU EMV 2014 30 EU R TTE 1999 5 EC RoHS 2011 65 EU UL Class I Divisi...

Page 17: ...et PC 1 x USB 2 0 port 1 x MicroSD card slot 1 x Micro SIM card slot 1 x Charging port DC 19 V 1 x Extension port for Add on module 1 x Port docking station Interfaces Docking station 4 x USB 2 0 1 x...

Page 18: ...to 140 F Air humidity 5 to 95 non condensing Class of protection EN IEC 60529 IP 65 Industry 4 1 4 Application development Creating a customer specific image All drivers for creating a dedicated image...

Page 19: ...0 2 dBi peak gain Frequency band 2402 MHz 2480 MHz 4 1 7 Data transmission LTE Module support is not provided for all required bands In terms of LTE support only data is supported no speech function V...

Page 20: ...setting Laser class CDRH IEC Class 2 laser and IEC Class 1M light Aiming LED VLD 655 Nm 10 nm Decode range 5 mil Code 39 100 UPC EAN 6 7 mil PDF 417 Decode range Skew pitch roll Skew tolerance 60 Pit...

Page 21: ...mbol Codes Code 11 Code 39 Aztec Micro PDF 417 Code 93 Code 128 Australian 4 state Maxi Code Codabar Coupon code Canadian 4 state PDF 417 Chinesisch 2 of 5 Discrete 2 of 5 Composite AB QR Code Interle...

Page 22: ...SO 18092 NFC Read Write ISO 15693 TI HF I Plus TI HF I Pro NXP I Code SLI NXP I Code SLI X Read Write ISO 14443 A NXP Mifare_One S50_4byte NXP Mifare_One S70_4byte NXP Mifare_One S50_7byte NXP Mifare_...

Page 23: ...0 C to 50 C 4 F to 122 F During charging 0 C to 40 C 32 F to 104 F Storage temperature 20 C to 50 C 4 F to 122 F Relative air humidity 45 to 85 non condensing Lifecycle 300 Charging hours Test conditi...

Page 24: ...2017 4 4 Product labelling Type label for devices in Zone 0 Type label for devices in Zone 0 External battery Laser warning for devices with 1D 2D Imager USB stick 8 GB Type 17 A1Z0 0007 MicroSD card...

Page 25: ...a rechargeable battery is influenced by various factors such as heat cold humidity harsh operating environments and falling from a great height When a rechargeable battery is stored for more than six...

Page 26: ...f delivery Tablet PC Agile X IS Dual stylus Power supply AC power cable EU US Cover module or external battery Quick start guide 6 1 1 Optional accessories Approved accessories for use in potentially...

Page 27: ...ly be charged outside potentially explosive atmospheres Use the external battery only for the purpose described in this user manual It is suitable only for the Agile X IS Tablet PC Never expose the re...

Page 28: ...Work steps 1 Place the Tablet PC with the front side display facing down on a flat surface Be careful not to scratch the display The power supply automatically switches from the external battery to th...

Page 29: ...chen auf Verwenden Sie ausschlie lich Akkus und Ladeger te die f r das Agile X IS von BARTEC zertifiziert sind Work steps 1 Pull out the folding metal bracket from the side of the cover a 2 Plug the p...

Page 30: ...ng Steady light fully charged LED red Steady light 15 to 30 remaining capacity Flashing 15 remaining capacity OFF No charging 6 3 4 Turn on Turn off the Agile X IS Turn on Press and hold the power but...

Page 31: ...unction key Fn1 Enter Home menu key Button Volume Right Home menu key Button Volume Left Home menu key Button Volume Function key Fn2 BIOS reset Clear CMOS Under Windows Combinations Functions Home me...

Page 32: ...first time make sure that the rechargeable battery has been fully charged 6 4 1 Windows 10 IoT Enterprise Work steps 1 Press the On Off button 2 Wait until the operating system has detected all of th...

Page 33: ...t the license conditions for the use of Windows and then click on I accept 4 Follow the individual steps for the installation system 6 5 Activating peripheral equipment A HotTab application offers fas...

Page 34: ...BARTEC Keep the side cover closed so that the protection class IP65 is guaranteed 6 6 1 Insert USB stick Work steps 1 Pull out the folding metal bracket from the side of the cover a 2 Insert the USB s...

Page 35: ...Remove replace screen protector Work steps 1 Lift a corner of the screen protector a and remove it from the display 2 Attach the screen protector in accordance with the Screen protector installation...

Page 36: ...cover module correctly inserted and locked Does the screen protector if used have the requisite certification Is the USB stick and the microSD card specified for the tablet PC Have only accessory par...

Page 37: ...switched off on request when you are in hospitals clinics or health establishments This is intended to avoid any possible interference with sensitive medical equipment 7 3 5 Heart pacemakers Manufact...

Page 38: ...omply with the following directive EN 60079 28 for LED safety 7 3 10 Restrictions in the case of wireless devices The use of wireless devices is possibly forbidden or restricted This applies primarily...

Page 39: ...5 250 5 350 MHz et 5 650 5 850 MHz et que ces radars pourraient causer du brouillage et ou des dommages aux dispositifs LAN EL FCC Anforderungen zum Schutz vor Hochfrequenz st rungen This device has b...

Page 40: ...ada have been satisfied Country approvals For 2 4 GHz products Europe covers Belgium Bulgaria Denmark Germany Estonia Finland France Greece Great Britain Ireland Iceland Italy Latvia Liechtenstein Lit...

Page 41: ...with the FCC guidelines with respect to exposure to high frequency energy the aerial for this transmitter should not be used in the direct vicinity of or in an operation unit with other transmitters a...

Page 42: ...whether the backlight settings may be too low Increase the backlight settings in the Tablet PC s control panel or using the HotTab application The screen suddenly switches off Check whether the extern...

Page 43: ...ettings of the 1D 2D Imager so that the HotTab tool has access The laser appears on the 1D 2D Imager but no data is displayed Check the distances between the 1D 2D Imagers and reduce them see chapter...

Page 44: ...that all data will be deleted Select Yes if you are absolutely certain that you have backed up your data 6 Wait until the recovery process is complete While the recovery process is running a command w...

Page 45: ...pection According to EN IEC 60079 17 and EN IEC 60079 19 the owner operator of electrical plants in potentially explosive atmospheres is obliged to have these plants checked by an electrician to ensur...

Page 46: ...form are available for download from our website http www bartec de Haben Sie Fragen Schreiben Sie uns eine E Mail oder rufen Sie uns an E Mail services bartec de Telefon 49 7931 597 444 10 Disposal T...

Page 47: ...0011 Carry system 03 9829 0101 Leather carry case 03 9829 0089 4 point belt 03 9829 0092 Shoulder strap 03 9829 0091 Accessories for use outside potentially explosive atmospheres Docking station 03 99...

Page 48: ...Declaration of Conformity Industry Tablet PC 10 1 Agile X IS Type 17 A1B EN 42 43 Subject to technical changes 05 2017 14 EU Declaration of Conformity...

Page 49: ...Industry Tablet PC 10 1 Agile X IS Type 17 A1B Declaration of Conformity Subject to technical changes 05 2017 EN 43 43...

Page 50: ...Your partner for safety technology Challenge us BARTEC GmbH Max Eyth Str 16 97980 Bad Mergentheim Germany Phone 49 7931 597 0 info bartec de www bartec de EN_11 A1B0 7D0001 05 2017 Automation 406842...

Reviews: