background image

 

Agile X Series 

Installation of HotTab Tool 

type 17-A1B4-.…/……..   or   B7-A234-4…/…….. 

 

  6/6 

Technical changes reserved.

Revision 0 – 05/2018

 

 

 

 

More information can be found on Microsoft page (msiexec):  

https://msdn.microsoft.com/en-us/library/windows/desktop/aa372024(v=vs.85).aspx

 

 
 

4.

 

Interface Assignment 

 

All modules what are built in and managed via HotTab are internal connected to COM ports. 
Following is the interface list and what modules are assigned. 
 

COM-Port 

Module 

Description 

COM 1 

RS232 I/O  

30-pin combo connector on Agile X 

COM 2 

RS232 I/O 

Expansion port on Agile X back sight 

COM 3 

HF Reader 

RFID HF RF521 reader optional build in Agile X 

COM 5 

WWAN module 

For available LTE modules 

COM 6 

WWAN module 

For available LTE modules 

COM 9 

GPS 

For build in GPS module 

COM 11 

RS232 I/O 

Docking connector on Agile X 

COM 12 

reserved 

COM 15 

Barcode Reader 

1D/2D Imager optional build in Agile X 

COM 20 

RFID UHF Add On Module  Build on optional on expansion port 

COM 21 

reserved 

COM 34 

reserved 

 

 

 

 

Reviews: