5.4
Terminal Assignment
DANGER
Non-certified accessories will endanger explosion protection.
In hazardous areas there is a risk of a fatal injury!
Use only original-accessories from BARTEC.
DANGER
Usage for purposes other than the intended purpose will endanger explosion
protection.
There is a risk of a fatal injury in an explosive atmosphere!
Ex power pack is factory-sealed and must not be opened.
An exception to this rule is the junction box!
Before commissioning make sure that the enclosure is completely sealed and
screwed securely.
Disconnect the junction box from voltage before opening it!
Disconnect from voltage before doing any connection or wiring work!
Only instructed qualified personnel may make any alterations to the pin assignment.
5.4.1
BCS 160
ex
Hand Scanner with Power Pack RS232/RS422 or USB
RS232/422 connetion cable
4-pin plug
Ex power pack
RJ45 pin
assignment
Wire
colour Signal
pin assignment
Designation
Terminal
Terminal
6
WH
TxD
3
RxD
X9
NC
-
shield
4
GND
X10
PE
X11
4
BR
GND
2
GND
X12
7
YE
+UB
1
+UB
X13
Anschlussleitung USB
4-pin plug
Ex power pack
RJ45 pin
assignment
Wire
colour
Signal
pin assignment
Designation
Terminal
Terminal
2
GN
D+
3
D+
X9
10
WH
D-
2
D-
X10
4
BK
GND
4
PE
X11
GND
X12
7
BR
+UB
1
+UB
X13
Summary of Contents for BCS 160 Series