Handscanners
BCS 3600
ex
series
4 Product description
Subject to technical modifications
17/05/18
31 / 72
4.6
Construction of the universal supply module
DANGER
Non-approved accessories!
Loss of function and risk of explosion.
Only use universal supply modules that have been specified for the relevant configuration by
BARTEC.
The approved accessories are shown in the system overview (see system overview, Chapter 15.2,
P. 70). The model is clearly indicated on the type label.
Fig. 11:
Construction of the universal supply module
Pos.
Description
Function
1
Cable gland
Feeding data cable to terminals
2
Cable gland
Feeding power cord to terminals
3
Terminals X1 to X2
Connecting 85 - 250 V
AC
power supply
4
7-pole round plug *
Connecting wired hand-held scanner
5
Cover
Protecting the terminal connection
chamber
6
DIP switch
Selecting the interface used
7
Terminals X5 to X9
Connecting the data line
8
Terminals X3 to X4
Connecting the 24 V
DC
power supply
*Is not needed with the Bluetooth version