4 Product description
Handscanners
BCS 3600
ex
series
32 / 72
Subject to technical modifications
17/05/18
4.6.1
Terminal assignment
Terminal assignment for installing power cords and RS 232, RS 422, RS 485 and USB types of
connection cable on the host PC side:
Terminal
Marking
RS 232
RS 422
RS 485
USB
Bluetooth
X1
L
L = 85 V
AC
- 250 V
AC
X2
N
N = Neutral conductor
X3 24
V
DC
+ 24
V
DC
+
X4 24
V
DC
– 24
V
DC
–
X5
TxD; RX–;TXRX–;
M (D–)
TxD RX– TXRX– M(D–) –
X6
RxD; RX+; P (D+) RxD
RX+
–
P (D+)
–
X7
RTS; TX-; TXRX+ RTS
TX–
TXRX+
–
–
X8 CTS;
TX+
CTS
TX+
– – –
X9 GND
GND
–
– – –
Tab. 16: Terminal connection plan for RS 232 / RS 422 / RS 485 / USB Ex e variants
The connection using the 7-pole round plug is configured as follows:
Terminal
Marking
Colour
1 +UB
Yellow
2 RxD
Green
3 TxD
White
4 RTS
Brown
5 CTS
Orange
6 – Grey
7
GND
Red / black
Tab. 17: Terminal connection plan for 7-pole round plug