BCS3600
ex
series
Hand-held scanner and accessories
Configuration
Subject to technical changes.
April 2022 / Revision C
137/164
9.6.3
Programming BCS3608ex with supply module Ex i - corded
Pos.
Description
1
Connecting cable BCS3608
ex
-IS
2
Hand-held scanner BCS3608
ex
-IS
Type: 17-A1S4-1HP0/**** (Zone 1/21)
3
Data cable in Ex i version between Ex-HMI (or other Ex device) and supply module
Ex i
this cable has to be provided by the customer
RS232
USB-SPP
4
Power supply
this cable has to be provided by the customer
5
Supply module Ex i corded for hand-held sanner
Type: 17-A1Z0-0025 (Zone 1/21)
6
Ex-HMI or other Ex device with Ex i interface
(approved for hazardous areas)
The supply module Ex i - corded transmits the data of the serial interface of the hand-held
scanner transparently (1 to 1), therefore changes of the settings on the module are not
necessary.
In order to establish a connection with a PC, it is necessary that the interface parameters
on the hand-held scanner and the PC/host are identical.
Adjustment on the hand-held scanner:
The interface parameters of the hand-held scanner can be adjusted using programming
codes in the Zebra product manual (chapter 7 or 9) or when using the Zebra 123 Scan
Utility (only when using a programming cable).
Adjustment on the supply module Ex i - corded:
No adjustment necessary, because UVM transparently forwards the data from the hand-
held scanner to PC/host.
Adjustment on PC/host:
The interface parameters from the PC/host can be adjusted via the settings e.g. in the
device manager, terminal program or application software.