12.2.3
Notes on resetting the hand-held scanners (only valid for BCS3678
ex
- Bluetooth)
When using "Set Factory Default" the following settings are not reset.
Multipoint-to-Point connection is not reset.
May have to be reset manually e.g. when updating the scanner firmware via Zebra
123 Scan Utility (only possible with activated point-to-point connection).
Existing pairing connections are not reset/deleted.
Must be done manually by using the barcode "Unpairing" in the Zebra "Product
Reference Guide".
When using "Set Factory Default" the following settings are reset.
When using the BCS3678
ex
-IS the barcode for the status LED has to be scanned to
adapt the LED display to the Ex modifications.
(Not necessary for devices with revision level 2 on the label)
Barcode to adjust the status LED display on the BCS3678
ex
-IS version:
12.3
Pairing with base station doesn’t work
Possible cause
Hand-held scanner is already connected to another base station.
Possible solution
Unpair the hand-held scanner from the base station or from the
PC/host to make the base station available for pairing with another
digital device.
Scan the barcode below to disconnect all existing hand-held
scanner connections to base station/PC host/other Bluetooth
devices.
Unpairing
Further information on pairing methods can be found in the corresponding Zebra
"Product Reference Guide" in Chapter 4 - "Radio Communication".
When "Factory Default Barcode" is scanned, all data is reset to factory settings but no
existing pairing connection is deleted.