Technical data
BCS3600
ex
series
Hand-held scanner and accessories
30/164
Subject to technical changes.
April 2022 / Revision C
4.3.2
Ambient conditions
4.3.2.1
Hand-held scanner
Operating temperature
Corded:
–20 °C to 50 °C (–4°F to 122 °F)
Bluetooth:
–20 °C to 50 °C (–4 °F to 122 °F)
Storage temperature
(without battery)
–40 °C to 70 °C (–40 °F to 158 °F)
Relative humidity
5 % - 95 %, condensing
Protection class (IEC 60529)
IP 65
Electrostatic discharge
EN 61000-4-2
±25 kV discharge via air
±10 KV direct discharge
±10 kV indirect discharge
Insensitivity towards ambient
light
0 to 108.000 Lux (direct sun radiation)
Maximum operating height
High altitude up to 2000 m above sea level
(normal altitude zero)
Mounting position/alignment:
hand-held equipment
For further technical data see technical data sheet.
4.3.2.2
Supply modules
Operating temperature
–20 °C to 50 °C (–4 °F to 122 °F)
Storage temperature
–40 °C to 70 °C (–40 °F to 158 °F)
Relative humidity
5 % - 95 %, condensing
Protection class (IEC 60529)
IP65
Electrostatic discharge
EN 61000-4-2
±25 kV discharge via air
±10 KV direct discharge
±10 kV indirect discharge
Insensitivity towards ambient
light
0 to 108.000 Lux (direct sun radiation)
Maximum operating height
High altitude up to 2000 m above sea level
(normal altitude zero)
Mounting position/alignment
permanently installed, no fixed alignment
Protection against dangerous
body currents
(overvoltage category)
The universal supply module and the supply
module Ex i correspond to overvoltage category
2 and pollution degree 1.
For further technical data see technical data sheet.
Summary of Contents for BCS3600ex Series
Page 1: ...Hand held scanner BCS3600ex series User Manual...
Page 2: ......
Page 4: ......
Page 173: ......