Technical data
BCS3600
ex
series
Hand-held scanner and accessories
34/164
Subject to technical changes.
April 2022 / Revision C
4.4.2
Connection of supply module Ex i to other Ex systems
This section lists the Ex-relevant parameters that are relevant for connecting the supply
module Ex i to another Ex system.
Ex-relevant input parameters for supply module Ex i
Input
Ex version
Power supply
Ex e
Data cable
Ex i (passive)
USB-SPP (Serial Port Profile)
RS232 (only TxD)
Type: 17-A1Z0-0025/**** + 17-A1Z0-0028/****
U
i
6 V
DC
I
i
500 mA
P
i
2 W
C
i
5,7 µF
L
i
0 µH
Ex i observation:
(so it is judged whether the values are compatible to each other)
Active
Interface
Values must relate to each other
as follows
Passive
Interface
U
o
≤
U
i
I
o
≤
I
i
P
o
≤
P
i
C
o
≥
C
i
L
o
≥
L
i