BCS3600
ex
series
Hand-held scanner and accessories
Commissioning
Subject to technical changes.
April 2022 / Revision C
71/164
6.10.1.4
Corded Hand-held scanner BCS3608
ex
-NI with HMI and HMI limiting cable (only
Zone 2 and 22)
Ex-relevant and functional parameters necessary for the function:
USB interface must provide 5 V/500 mA on the output side.
RS232 interface needs a separate power supply with 5 VDC/500 mA.
If these values are not provided by the interface, the connection can be realized via a
universal supply module.
Pos. Description
1
HMI (approved for a potentially explosive atmosphere)
2
HMI Limiting cable USB (B7-A2Z0-0041 or B7-A2Z0-0054)
or
HMI Limiting cable RS232 (B7-A2Z0-0040 or B7-A2Z0-0050)
3
Hand-held scanner BCS3608
ex
-NI
The limiting cable that is connected to the HMI is used for data transfer and power supply.
This connection is only approved for Zone 2, 22 and Division 2.
Requirements
Cable for power supply and data line in Ex e:
Must be mechanically protected for installation.
Plug connection (USB or RS232):
Must be mechanically protected against accidental loosening/pulling.
Connection:
The connection must be made in an Ex-tested terminal compartment.
Summary of Contents for BCS3600ex Series