BCS3600
ex
series
Hand-held scanner and accessories
Commissioning
Subject to technical changes.
April 2022 / Revision C
87/164
6.11.11
Permissible connection cable diameters
Possible cable dimensions for the cable gland on the supply module
Power supply
Terminals X1 to X2
Cable gland
Cable
diameter
100 V
AC
to 240 V
AC
±10% 50/60 Hz
Ex e M16x1,5 (black)
4,5 - 9 mm
Power supply
Terminals X3 to X4
Cable gland
Cable
diameter
24 V
DC
±10%
Ex e M16x1,5 (black)
4,5 - 9 mm
Interface
Terminals X5 to X10
Cable gland
Cable
diameter
Shield
diameter
USB-SPP
Ex e M16x1,5 (black)
4,5 - 5,7 mm
3 - 6 mm
RS232
4,5 - 9 mm
3 - 6 mm
RS422
4,5 - 9 mm
3 - 6 mm
RS485
4,5 - 9 mm
3 - 6 mm
Summary of Contents for BCS3600ex Series
Page 1: ...Hand held scanner BCS3600ex series User Manual...
Page 2: ......
Page 4: ......