background image

BCS 36x8

ex

 

Connection to PLC 

 

 

Technical changes reserved. 
04/2019 

5/10 

 

2.

 

Connection to PLC 

 

 

Compatibility with other components or systems: 
BARTEC tested only the components described in chapter 3 of this document. 
We expect that communication is in general possible with all other PLC and necessary communication 
modules. 
Detailed instructions can be found in the descriptions of the respective manufacturers.

 

 

 

BARTEC cannot give any further instructions for the processing of the data. 
Further processing of the data is the responsibility of the operator.

 

 
 

3.

 

Sample Project for Siemens-Simatic S7-300 

 
A sample project is available for a Siemens-SIMATIC S7-300 with CPU 315-2 PN/DP central processing unit 
The project is available as a download on the BARTEC support download page. 

http://automation.bartec.de/scannerE.htm

 

 

Data Capture 

 

BCS3600ex Hand-Held Scanner Series 

 

Programming 

 

Sample for PLC Siemens SIMATIC S7-300 CPU315 2 PN/DP and CP340 

 
The sample shows what is necessary to establish a connection and what settings are required. 
Further information can be found in Siemens documentation. 

https://support.industry.siemens.com/cs/document/99741983/sample-program-(standard-blocks-cp-340-cp-341)-
zxx21_01_ptp_com_cp34x-zip-for-step-7-(tia-portal)?dti=0&lc=en-DE

 

 

 

Siemens and TIA-Portal are registered trademarks.

 

 
 
 

 

Summary of Contents for BCS36x8ex Series

Page 1: ...ernet www bartec de Supplementary description Translation of the original Addendum to user manual 11 A1S4 7D0001 BCS36x8ex Series Type 17 A1S4 HP ATEX IECEx Zone 1 21 CSA Class I II III Division 1 Typ...

Page 2: ...al information for the connection to PLC 3 2 Connection to PLC 5 3 Sample Project for Siemens Simatic S7 300 5 3 1 Sample project 6 3 2 Hardware Configuration 6 3 3 Software Configuration 7 3 4 Projec...

Page 3: ...otocol There is no compatibility list existing The following must be observed when connecting the handheld scanner to a PLC What interfaces are available on the PLC PLC The USM supports the following...

Page 4: ...e 1 Availability on the PLC side Communication controller processor CP Open ASCII driver Solution 2 availability on the PROFIBUS DP side Figure 2 Availability on the DP side PROFIBUS DP converter to s...

Page 5: ...3 Sample Project for Siemens Simatic S7 300 A sample project is available for a Siemens SIMATIC S7 300 with CPU 315 2 PN DP central processing unit The project is available as a download on the BARTEC...

Page 6: ...p file Can be opened by using the Siemens software can be found under the TAB Project and navigate to Project and Retrieve 3 2 Hardware Configuration The sample project Test Scanner 01 zap15 is create...

Page 7: ...reserved 04 2019 7 10 3 3 Software Configuration It s important to know that the serial interface parameters on all connected devices are identical Setup Right click on the CPU 315 2 PN DP Properties...

Page 8: ...BCS 36x8ex Connection to PLC 8 10 Technical changes reserved 04 2019 3 4 Project tree for necessary modules The project tree shows all the necessary modules...

Page 9: ...ection to PLC Technical changes reserved 04 2019 9 10 3 5 Main OB1 In OB1 with command call the routine for receiving of data is started 3 6 Function FC7 RCV_RS232C The function FC7 control the handli...

Page 10: ...arcode data Status Feedback from the module according to Siemens Barcode Scanner 0 25 Data defined as CHAR Length can free defined In sample 0 25 End of String End character In this sample defined as...

Reviews: