background image

Scope : 

USER MANUAL 
DE8-BC Ex d Empty Enclosure 

 

      

 

Date: 

02.04.2022 

Ver.: 

QA Code: 

5

 

Checked by: 

E.T. 

Approved by: 

S.Gr. 

Page: 

of 8

 

Document no. : 

21469 

 
 

The passing on and copying of this document and the use or communication of it’s contents are forbidden without express authority. 
Offenders are liable to payment of damages. All rights are  reserved in the event of the registration of a patent . 

The DE8-BC range of Ex d enclosures are rugged and designed for harsh environment 
like: 

  Oil and gas industry 

  Chemical industry 

  Pharmaceutical 

  Industry 

  Agribusiness 

 

They are designed for use in potentially explosive atmospheres and certified according to the 
requirements of the ATEX Directive and IECEx. 

Parameters relating to safety 

Maximum current 

 

1000 A 

Maximum DC voltage  

1000 V 

Maximum AC voltage  

11000 V 

  

Marking 

Ex db IIB Gb 
Ex tb IIIC Db 

Tamb. : -40°C *, to +60°C 
IP66 

*except enclosures type DE8-BC75D and DE8-BC86D which are only certified to -20°C 

 

The enclosures listed in this manual are certified: 

            II 2 G/D (ATEX) 
            Gb / Db (IECEx) 

 
The certificate numbers are :

 

INERIS 09ATEX9017U 
IECEx INE 13.0001U 

 

They are made in accordance with the following standards: 
 

Zones due to gases, vapors and mists  

EN IEC 60079-0:2018   

 

IEC 60079-0:2017 

EN 60079-1:2014 

 

 

IEC 60079-1:2014 

 

Zones for dusts 

EN IEC 60079-0:2018   

 

IEC 60079-0:2017

 

EN 60079-31:2014 

 

 

IEC 60079-31:2013 

 

Summary of Contents for DE8-BC Series

Page 1: ...S Gr Page 1 of 8 Document no 21469 The passing on and copying of this document and the use or communication of it s contents are forbidden without express authority Offenders are liable to payment of...

Page 2: ...d for use in potentially explosive atmospheres and certified according to the requirements of the ATEX Directive and IECEx Parameters relating to safety Maximum current 1000 A Maximum DC voltage 1000...

Page 3: ...ructions The device must be installed used and maintained in accordance with the following standards IEC EN 60079 0 Explosive atmospheres Part 0 Equipment General requirements IEC EN 60079 1 Explosive...

Page 4: ...the carrier Do not put damaged products into service Packaging Location storage Duration storage Open In a covered location clean without contact with external substances and closed with temperature a...

Page 5: ...5 192 274 346 12 14 x M12 35 85 DE8BC 351D 358 478 471 33 250 350 225 192 274 346 12 14 x M12 35 98 DE8BC 43 438 538 321 40 380 400 300 252 334 526 12 14 x M12 35 122 DE8BC 43D 438 538 472 63 380 400...

Page 6: ...Nm 20 C 40 C Qty x L 20 C 40 C DE8BC 32 800 800 12 x M12 35 74 74 DE8BC 32D 800 800 12 x M12 35 74 74 DE8BC 351 800 800 14 x M12 35 74 74 DE8BC 351D 800 800 14 x M12 35 74 74 DE8BC 43 800 800 14 x M1...

Page 7: ...s A C Sides B D Max 2 Sides A C Sides B D Max 2 DE8BC 32 12 12 32 8 8 20 3 3 12 1 1 4 DE8BC 32D 12 12 32 8 8 20 3 3 12 1 1 4 DE8BC 351 12 12 24 8 8 18 3 3 8 1 1 4 DE8BC 351D 12 12 24 8 8 18 3 3 8 1 1...

Page 8: ...the content of the Ex component enclosure equipment may be placed in any arrangement provided that an area of at least 20 IIB or 40 IIB H2 of each cross sectional area remains free The length of flame...

Reviews: