background image

Scope : 

USER MANUAL 
DE8-BC Ex d Empty Enclosure 

 

      

 

Date: 

02.04.2022 

Ver.: 

QA Code: 

5

 

Checked by: 

E.T. 

Approved by: 

S.Gr. 

Page: 

of 8

 

Document no. : 

21469 

 
 

The passing on and copying of this document and the use or communication of it’s contents are forbidden without express authority. 
Offenders are liable to payment of damages. All rights are  reserved in the event of the registration of a patent . 

Number of cable entries: 

  Any  type  of  cable  or  conduit  entry  device  certified  Ex  d  can  be  used  and  installed 

according to EN / IEC 60079-14 

  Different types of threads can be used but minimum five threads by bolt must always 

been engaged 

 

Metric 

M20 ISO 

M25 ISO 

M32 – M40 – M42 

ISO  

M50 ISO 

M63 ISO 

M75 ISO 

NPT 

½ ‘’ NPT 
¾ ‘’ NPT  

1 ‘’ NPT 

1’’ ¼ NPT 
1’’ ½ NPT 

2 ‘’ NPT 

(1) 

2 ‘’ ½ NPT 

(1) 

3 ‘’ NPT 

(1) 

 

Product code 

Sides 

A & C 

Sides 

B & D 

Max 

(2) 

Sides 

A & C 

Sides 

B & D 

Max 

(2) 

Sides 

A & C 

Sides 

B & D 

Max 

(2) 

Sides 

A & C 

Sides 

B & D 

Max 

(2) 

Sides 

A & C 

Sides 

B & D 

Max 

(2) 

Sides 

A & C 

Sides 

B & D 

Max 

(2) 

 

 

DE8BC  32 

12 

12 

32 

20 

12 

 

DE8BC  32D 

12 

12 

32 

20 

12 

 

DE8BC  351 

12 

12 

24 

18 

 

DE8BC  351D 

12 

12 

24 

18 

 

DE8BC  43 

18 

18 

36 

14 

14 

28 

16 

 

DE8BC  43D 

18 

18 

36 

14 

14 

28 

16 

 

DE8BC  44 

20 

20 

40 

16 

16 

30 

20 

 

DE8BC  44D 

20 

20 

40 

16 

16 

30 

20 

 

DE8BC  54 

20 

20 

40 

16 

16 

30 

20 

 

DE8BC  54D 

20 

20 

40 

16 

16 

30 

20 

 

DE8BC  64 

28 

28 

60 

18 

18 

50 

28 

 

DE8BC  64D 

28 

28 

60 

18 

18 

50 

28 

 

DE8BC  75 

28 

28 

72 

24 

24 

72 

10 

10 

40 

11 

 

DE8BC  75D 

28 

28 

72 

24 

24 

72 

10 

10 

40 

11 

 

DE8BC  86 

32 

32 

112 

28 

28 

100 

20 

20 

80 

17 

 

DE8BC  86D 

32 

32 

112 

28 

28 

100 

20 

20 

80 

17 

 

DE8BC  107 

36 

36 

112 

32 

32 

100 

20 

20 

80 

17 

10 

 

DE8BC  108 

36 

36 

112 

32 

32 

100 

20 

20 

80 

17 

10 

 

DE8BC  108D 

36 

36 

112 

32 

32 

100 

20 

20 

80 

17 

10 

 

(1) With welded ring 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

(2) Maximum number of cable entries on all side walls of the enclosure 

  

  

  

  

  

  

  

  

  

  

 

 

Summary of Contents for DE8-BC Series

Page 1: ...S Gr Page 1 of 8 Document no 21469 The passing on and copying of this document and the use or communication of it s contents are forbidden without express authority Offenders are liable to payment of...

Page 2: ...d for use in potentially explosive atmospheres and certified according to the requirements of the ATEX Directive and IECEx Parameters relating to safety Maximum current 1000 A Maximum DC voltage 1000...

Page 3: ...ructions The device must be installed used and maintained in accordance with the following standards IEC EN 60079 0 Explosive atmospheres Part 0 Equipment General requirements IEC EN 60079 1 Explosive...

Page 4: ...the carrier Do not put damaged products into service Packaging Location storage Duration storage Open In a covered location clean without contact with external substances and closed with temperature a...

Page 5: ...5 192 274 346 12 14 x M12 35 85 DE8BC 351D 358 478 471 33 250 350 225 192 274 346 12 14 x M12 35 98 DE8BC 43 438 538 321 40 380 400 300 252 334 526 12 14 x M12 35 122 DE8BC 43D 438 538 472 63 380 400...

Page 6: ...Nm 20 C 40 C Qty x L 20 C 40 C DE8BC 32 800 800 12 x M12 35 74 74 DE8BC 32D 800 800 12 x M12 35 74 74 DE8BC 351 800 800 14 x M12 35 74 74 DE8BC 351D 800 800 14 x M12 35 74 74 DE8BC 43 800 800 14 x M1...

Page 7: ...s A C Sides B D Max 2 Sides A C Sides B D Max 2 DE8BC 32 12 12 32 8 8 20 3 3 12 1 1 4 DE8BC 32D 12 12 32 8 8 20 3 3 12 1 1 4 DE8BC 351 12 12 24 8 8 18 3 3 8 1 1 4 DE8BC 351D 12 12 24 8 8 18 3 3 8 1 1...

Page 8: ...the content of the Ex component enclosure equipment may be placed in any arrangement provided that an area of at least 20 IIB or 40 IIB H2 of each cross sectional area remains free The length of flame...