Flow Meter MID type 6823-x
105
Measuring System MAK TIGER 3003 Service manual, SA 131128, 10.03.2020
Important information for assembly/disassembly:
When installing MID units with dairy pipe thread connections, it is essential to
follow the instructions below in the order listed in order to prevent strong me-
chanical forces on the MID unit (which can damage or destroy the unit).
Installation:
First remove the threaded milk pipe adapter, if still attached to the MID. To
do this, open the fastening clamps (2) on both sides and remove the pipe
connections from the MID.
Attention:
Do not lose the seals and put them back carefully when reassembling.
First screw the threaded milk pipe adapters with the union nuts on both
sides of the pipe connections.
Then fit the MID (not forgetting the flat gaskets (5)) and secure with the
fastening clamps (2). It might be easier if the pipe supports/anchors are
slightly loosened first.
Tighten again at the end.
Disassembly:
First take out the MID by removing the fastening clamps (2) on both sides.
It might be easier if the pipe supports/anchors are slightly loosened first.
If necessary at this point, take off the threaded milk pipe adapters by
undoing the union nuts.
Attention:
Do not lose the seals and put them back carefully when reassembling.