ULTRASAMPLER® sample collection system
188
Measuring System MAK TIGER 3003 Service manual, SA 131128, 10.03.2020
Removing the sampler
Undo union nut on intake cannula and detach pump hose.
Unplug sampler connection cable.
Unscrew and remove the two M8 x 20 pan head screws on the underside
of each sampler holder and remove sampler.
Removing the branch pipe (with or without sampler)
Undo the fittings holding the branch pipe on the cover of the sample
collection box.
If the sampler is also being removed, unplug the sampler connection
cable.
Loosen additional milk pipe restraint outside the sample collection box
(where fitted) until the milk pipeline has some side clearance.
Remove fasteners from the branch pipe flanges and remove branch pipe
(with or without sampler).
Installation of flow level meter, type 6826
The flow level meter sits between the branch pipe of the sampler and the
flow-calming section and is mounted on both sides.
The milk taken into the collection vehicle flows through the flow level meter
first and then through the sampler. See section 26.3.2. for installation in-
structions.
Note:
Mount the flow level meter in such a way that the terminal box remains
ac-cessible.
If space is limited, fit the connection cable before installing the meter.
Demontage Flow Level Meter Typ 6826
Caution:
Never remove the flow level meter while the collection vehicle is running
and the MAK 3003 LYNX system is switched on!
Removing the flow level meter
Undo any locks on the milk pipeline outside the sample collection box
(to generate axial play).
Disconnect the connection cable.
Resolve clamps on the flanges and take out flow level meter.