Measuring system MAK TIGER 3003
30
Measuring System MAK TIGER 3003 Service manual, SA 131128, 10.03.2020
5.7.1
Information on the pneumatic system
In order to comply with food regulations, it is necessary to check the heavy-
duty filter on component 292870 (air intake filter unit) to ensure proper drain-
age of condensation and to check the contamination indicator for signs of
discolouration once a week.
Weekly checks are also required on the ejector control valve, the ejector and
the V3, V5 and V10 valves to ensure that they are all working correctly. This
is simply done by vacuum testing.
Any components showing signs of abnormality (heavy-duty filter, ejector,
valves, control valve) must be replaced immediately!
Caution:
It is illegal to operate the system with defective components under food regulations!
It is also essential to ensure that all the oils used in the pneumatic system
and any additives which may get into the pneumatic system, including any
antifreeze agents, are confirmed absolutely safe for use in food production
processes and comply with the relevant standards.