Milk sensor, series B type 6703-15
90
Measuring System MAK TIGER 3003 Service manual, SA 131128, 10.03.2020
10.3
Assembly/ Installation
Installation in the tank or pipe wall by means of welding socket Type 6701-00-
021 as follows:
Weld the welding socket into the tank or pipe wall, smooth and clean the
seams.
Slightly grease the O-ring D 12.0 x 3.0 VMQ 70 FDA (Order No. 335326)
supplied with the milk sensor, insert it into the welding socket and insert it
carefully with the fingertip into the O-ring groove at the front end. Check
correct, even fit by fingertip scanning.
Carefully cut the electrode rod of the milk sensor with an iron saw to the
required length without damaging the insulation and strip off approx. 1.5
cm. Then deburr and smooth the interface.
Required length:
When installed in the pipe, the measuring tip should end in the middle of
the pipe, when installed in other containers according to functional
requirements.
Push the clamp gasket DN 20 EPDM onto the sensor tip and carefully
insert the sensor into the weld-in socket with slight left / right turns as far
as it will go.
Locking the sensor with a double-jointed clamp, only tighten the
thumbscrew "hand-tight".