POLARIS COMFORT
- for Zone 1/21
POLARIS Touch Panel 5.7" / 10.4" / 12.1"
Installation
Technical data subject to change.
06/2017
EN 29/57
6.6.5
BARTEC PROFIBUS-DP interface (optional)
Configuration PROFIBUS-DP
Terminal Interface
Signal
Remarks
X17
not connected
X18
not connected
X19
Interface COM 1 Termination B2 Bridge for terminating network (B1-B2)
X20
Interface COM 1 Termination A2 Bridge for terminating network (A1-A2)
X21
Interface COM 1 Termination B1 Bridge for terminating network (B1-B2)
X22
Interface COM 1 Termination A1 Bridge for terminating network (A1-A2)
X23
Interface COM 1 Out B
Signal B Output
X24
Interface COM 1 Out A
Signal A Output
X25
Interface COM 1 In B
Signal B Input
X26
Interface COM 1 In A
Signal A Input
Connection of a controller via the PROFIBUS-DP interface of the POLARIS.
Maximum line length: see PNO specification.
Pins 26-24-22, 25-23-21 are already connected inside.
See the interface description from the controller manufacturer for the relevant pin
assignment of the controller.
Summary of Contents for POLARIS COMFORT Series
Page 1: ...User Manual POLARIS COMFORT 5 7 up to 12 1 Zone 1 Zone 21...
Page 2: ......
Page 6: ...blank...