1.  Description 

The "RFID Snap-on Module" reads and writes RFID tags. It was designed for 

the Mobile Computer MC 959x series. 

 

 

A  C#  package  containing all the 

components and resources that are 

required  for software  integration  is 

available to software  developers.  A 

demonstration  program  (programmed  in 

Visual Studio 2008) in Open Source 

makes it possible to conduct a simple 

demonstration and test for correct 

functioning. 
 

Type 

RFID frequency range 

LF 

125 kHz / 134 kHz 

HF 

13.56 MHz 

UHF (EU) 

865.6 to 867.5 MHz 

UHF (US) 

902 to 928 MHz 

 

The RFID reader is supplied voltage through the external interface at the back 

of the MC 959x. Data communication is enabled by the USB interface. 
The reader is available in a standard version (non-Ex) and in an explosion-

proof version. 

 

Device 

Configuration  

Motorola Solutions 

Device 

Configuration 

BARTEC 

MC 9590  Standard version 

MC 9590

ex

-NI  Ex-proof 

MC 9596  Standard version GSM  

MC 9596

ex

-NI  Ex-proof GSM  

MC 9598  Standard version CDMA  

MC 9598

ex

-NI  Ex-proof CDMA  

 

Use in Accordance with the Intended Purpose 

The RFID Snap-on Modules are electrical apparatus designed as accessories 

for the hand-held mobile computers in the MC 959x and MC 959x

ex

-NI series. 

The modules can be used only  in  combination  with  the  Mobile Computer. 

They capture, process and transmit data inside and outside hazardous areas.  
  
Available for: 

 

Standard version – not explosion-proof 

 

ATEX/IECEx Zone 2 and Zone 22 

 

UL Class I, II Division 2, Class III  

 

It  is  used exclusively in  combination with operating equipment items  which 

conform to the requirements of Overvoltage Category I. 

 

Other applicable documents 

-

 

Technical data sheet for the explosion-proof and standard 

versions of the RFID snap-on module 

-

 

Description of BARTEC’s Open Source software packet 

for RFID snap-on module implementation in one customer 

application. 

-

 

Technical data sheet for the explosion-proof version of the 

MC 959x

ex

-NI Mobile Computer series  

-

 

User manual for the MC 959x Mobile Computer series 

The retention of these documents is mandatory! 

 

2. Safety Instructions 

The "RFID Snap-on Module" may be operated only if it is clean and free of 

any damage and only within the specified temperature class and  the 

temperature  range indicated for it.  It is essential to comply with the 

permissible operating data for the device being used. Utilisation in areas other 

than those specified and the modification of the product by anyone other than 

the manufacturer is not permitted and will exempt BARTEC from liability for 

defects and any further liability. The generally applicable statutory rules and 

other binding directives relating to workplace safety, accident prevention and 

environmental protection must be observed. 

Danger, Warning and Information Symbols 

Safety instructions and warnings are specially highlighted in this manual and 

marked by symbols.  

  

DANGER 

DANGER  indicates a hazardous situation 

which, if not avoided, will result in death or 

serious injury. 

 

 

WARNING 

WARNING  indicates a hazardous situation 

which, if not avoided, could result in death or 

serious injury. 

 

 

CAUTION 

CAUTION  indicates a hazardous situation 

which, if not avoided, could result in minor or 

moderate injury. 

 

 

ATTENTION 

ATTENTION  identifies a potentially 

damaging situation which, if not avoided, 

could damage the equipment or something in 

its environment. 

 

 

 

Important instructions and information on effective, economical and 

environmentally compatible handling. 

3. Technical Data  

Explosion Protection 

ATEX Zone 2 and Zone 22 and IECEx Zone 2 and 22 

Types 

B7-A2Z0-0020 

B7-A2Z0-0022 

B7-A2Z0-0021 

B7-A2Z0-0023 

ATEX approval 

EPS 13 ATEX 1588 X 

ATEX marking 

  II 3G Ex ic IIC T6 Gc 
  II 3D Ex ic IIIC T90°C Dc 

IECEx approval 

IECEx EPS 13.0028 X 

IECEx marking 

Ex ic IIC T6 Gc 

Ex ic IIIC T90°C Dc 

Directives 

94/9/EC 

Standards 

EN 60079-0 

EN 60079-11 

UL Class I Division 2 

Types 

B7-A2Z0-0020 

B7-A2Z0-0022 

B7-A2Z0-0021 

B7-A2Z0-0023 

UL approval 

E321557 

UL marking 

Class I Division 2 groups A, B, C and D 

Class II Division 2 groups F and G 

Class III 

Temperature class 

T5 

Special Conditions for ATEX and UL 

It is not permissible to attach or remove the RFID Snap-on Module inside 

the hazardous area. 

Conditions particulières applicables aux équipements ATEX et UL 

Il est strictement interdit de clipser ou déclipser le module RFID en zone 

dangereuse. 