ALPHA FLOOR GRINDER
OWNER’S MANUAL AND PARTS BOOK
7
OIPB
– C15001
ROUTINE SERVICE SCHEDULE
Routine Service Intervals
Each
Use
After 1.5
months
or 50 hrs
Each 3
months
or 100
hrs
Each 6
months
or 200
hrs
Each 9
months
or 300
hrs
Each 12
months
or 400
hrs
General Inspection
Guards
Check
O
O
O
O
O
Warning Stickers
Check
O
O
O
O
O
Test Run
Check Operation
O
O
O
O
O
Fasteners
Check Tightness
O
Electrical
Cord
Check for
Damage
O
Plug
Check for
Damage
O
Switches/Buttons
Check
O
Grinding Components
Tooling
Check Life
O
Drive Coupling
Check for
Damage
O
Tooling Plate
Check
O
O
O
O
Motor
Fan
Check - Clean
O
O
O
O
O
ROUTINE SERVICE INTERVALS
Due to the nature and environment of use, Floor Grinders could be exposed to severe
operating conditions. Some general maintenance guidelines will extend the useful life of your
machine.
• The initial service for your grinder should be performed after 25 hours of use, at which time
your mechanic (or authorized repair shop) should complete all the recommended checks in the
schedule above. The maintenance log is handy for keeping a record of the maintenance
performed and the parts used for servicing your grinder.
• Regular service according to the schedule above will prolong the life of the floor grinder and
prevent expensive repairs.
• Keeping your floor grinder clean and free from debris is the single most important regular
maintenance operation, over and above the checks in the service schedule above, that can be
performed. After each use your grinder should be cleaned to remove any dust and debris from
the undercarriage and surrounding components.
• In the Service Schedule above, items that should be checked, replaced or adjusted are
indicated by “o” in the appropriate column. For ease of recording place, a checkmark through
the “o” when the item is complete. If an item is not required or not completed place an “x”
through the “o” in the box.
• Failure to have your floor grinder regularly serviced and properly maintained in accordance
with the manufacturer’s instructions will lead to premature failure and void the warranty.