background image

ALPHA FLOOR GRINDER 

 

OWNER’S MANUAL AND PARTS BOOK 

 

 

OIPB 

– C15001

 

ROUTINE SERVICE SCHEDULE 

 

Routine Service Intervals 

Each 

Use 

After 1.5 

months 

or 50 hrs 

Each 3 

months 

or 100 

hrs 

Each 6 

months 

or 200 

hrs 

Each 9 

months 

or 300 

hrs 

Each 12 

months 

or 400 

hrs 

General Inspection 

 

Guards 

Check 

 

Warning Stickers 

Check 

 

Test Run 

Check Operation 

 

Fasteners 

Check Tightness 

 

 

 

 

 

Electrical 

 

Cord 

Check for 
Damage 

 

 

 

 

 

Plug 

Check for 
Damage 

 

 

 

 

 

Switches/Buttons 

Check 

 

 

 

 

 

Grinding Components 

 

Tooling 

Check Life 

 

 

 

 

 

Drive Coupling 

Check for 
Damage 

 

 

 

 

 

Tooling Plate 

Check  

 

 

Motor

 

 

 

 

 

 

 

Fan 

Check - Clean 

 

 

ROUTINE SERVICE INTERVALS 

 
Due to the nature and environment of use, Floor Grinders could be exposed to severe 
operating conditions. Some general maintenance guidelines will extend the useful life of your 
machine.  
 
• The initial service for your grinder should be performed after 25 hours of use, at which time 
your mechanic (or authorized repair shop) should complete all the recommended checks in the 
schedule above. The maintenance log is handy for keeping a record of the maintenance 
performed and the parts used for servicing your grinder.  
• Regular service according to the schedule above will prolong the life of the floor grinder and 
prevent expensive repairs.  
• Keeping your floor grinder clean and free from debris is the single most important regular 
maintenance operation, over and above the checks in the service schedule above, that can be 
performed. After each use your grinder should be cleaned to remove any dust and debris from 
the undercarriage and surrounding components.  
• In the Service Schedule above, items that should be checked, replaced or adjusted are 
indicated by “o” in the appropriate column. For ease of recording place, a checkmark through 
the “o” when the item is complete. If an item is not required or not completed place an “x” 
through the “o” in the box.  
• Failure to have your floor grinder regularly serviced and properly maintained in accordance 
with the manufacturer’s instructions will lead to premature failure and void the warranty. 

Summary of Contents for CONTEC ALPHA

Page 1: ...Doc OIPB C Orig Rel 11 2018 Curr Rev 00 FLOOR GRINDER ALPHA OWNER S MANUAL AND PARTS BOOK www BARTELLGLOBAL com...

Page 2: ...e Kentucky USA 40209 Tel 425 405 9100 Fax 425 405 9101 ORIGINAL LANGUAGE OPERATING MANUAL FOR CONTEC FLOOR GRINDER 2019 Bartell Morrison Inc No part of this work may be reproduced or transmitted in an...

Page 3: ...ngine is operating or shortly after it is turned off Serious burns may occur CAUTION ROTATING HAZARD Never place hands or feet inside safety guard rings Serious injury will result from contact with ro...

Page 4: ...UTINE SERVICE PLAN 6 o ROUTINE SERVICE SCHEDULE 7 o ROUTINE SERVICE INTERVALS 7 OPERATING SAFETY PRECAUTIONS 8 OPERATION INSTRUCTIONS 9 o SETTING UP YOUR ALPHA GRINDER 9 o PRIOR TO OPERATION 9 o CHANG...

Page 5: ...you many years of satisfied use WARRANTY INFORMATION Bartell agrees to furnish without charge F O B our plant a replacement for any part or portion thereof comprising the main unit of the Contec Floor...

Page 6: ...IONS ALPHA Dimensions Grinding Width mm in 230 9 Overall Width mm in 30 12 Overall Length mm in 60 24 Overall Height mm in 51 20 Weight Weight kg lb 42 93 Performance Speed of Grinding Head RPM 1680 P...

Page 7: ...t After reading through this manual thoroughly you will find that you can do some of the regular maintenance yourself However when in need of parts or major service be sure to see your Bartell dealer...

Page 8: ...ic or authorized repair shop should complete all the recommended checks in the schedule above The maintenance log is handy for keeping a record of the maintenance performed and the parts used for serv...

Page 9: ...tor must wear a mask In all other cases the grinder must be operated with the safety ring The operator should never leave the machine unattended during operation Before leaving the machine all rotary...

Page 10: ...e given to the bottom of the machine where the tooling plate is located Check all bolts and screws for tightness and make sure all bolts and screws are securely tightened Loose bolts and screws may ca...

Page 11: ...ched full speed place the grinding head carefully on the floor If the machine is correctly adjusted see above it is easy to move across the floor If the machine pulls to the left or right the machine...

Page 12: ...ALPHA FLOOR GRINDER OWNER S MANUAL AND PARTS BOOK 11 OIPB C15001 PARTS LIST 1 ALPHA GRINDER...

Page 13: ...100600 FAN COVER PROTECTION 2 33 8704100800 SPACER 1 35 8790200024 STRAIN RELIEF 1 37 879009SW6 ALLEN KEY 6 MM 1 50 8761330000 WASHER M10 23 52 8761320003 NUT NYLON M10 8 54 8761330033 WASHER SERRATED...

Page 14: ...2 ALPHA GRINDER CANADA ONLY ALPHA GRINDER PARTS LIST 2 CANADA ONLY ALPHA GRINDER PARTS LIST 2 Item Part Description QTY Remarks 95 8750201008 CSA PROTECTION KIT CANADA ONLY 1 Includes Item 96 97 96 87...

Page 15: ...ALPHA FLOOR GRINDER OWNER S MANUAL AND PARTS BOOK 14 OIPB C15001 This Page Left Intentionally Blank...

Page 16: ......

Reviews: