Technical Data

Operating Voltage: 7 - 24 Volt (+ 5%), stabilised. 

Important: The used power supply must be able to bear pulsed loads. Unstabilised or to weak power
supplies can cause unwanted flickering effects, especially during colour changes!

Module current (without LED lamps): ca. 20 mA

Operating temperature: 0°C  -  max.  +50°C  (recommended:  <=  30°C)  (Use  only  in  dry  places  with
sufficient air ventilation)

Modulation  system:  The  Chromoflex  modules  are  based  on  a  digital  System,  named
„Vector-Fractal-Modulation“  or  „VFM“.  This  modulation  system  was  optimised  for  minimising  load  on
power  supplies  and  has  considerable  advantages  compared  to  traditional  systems.  The  modulation
frequency is in the range from 120 Hz  up to (max.) 240 Hz. Patent pending.

Maximum cable inductance  can be calculated as L_max = 40µH/(maximum current). Note: Standard
control cable normally has an inductance of around  0.4-0.8 µH/Mtr.

Model  „I350“

Pulsed constant current abt. 350 mA (+ 5%, -20%) per channel ( 3 channels).

Model „Stripe“

Pulsed constant voltage, maximum current 2.5 Ampere per channel (3 channels) at 12 Volts, and 1.25
Ampere per channel at 24 Volts.

Contact / Internet

Download of PC-Software, data sheets , technical support:

www.chromoflex.com , www.barthelme.de

Contact (technical support only by Internet / Email):

www.barthelme.de

Chromoflex - Manual  - English V1.07 

- www.barthelme.de

Rev. 02.07.2006

- 12 -

Summary of Contents for CHROMOFLEX I350

Page 1: ...ng Chromoflex comes with several built in effects from calming colour change up to show effects External manual buttons DIP switches or a PC software can be used to control the modules Up to 30 module...

Page 2: ...rs marking obligation Particularly in connection with optics also weak LEDs can become very dangerous Staring into LEDs can cause irreparable damage to the eye s retina Hence NEVER STARE INTO THE BEAM...

Page 3: ...LEDs in series most high power LEDs for 350mA constant current require around 3 3 7 Volts depending on the colour type and manufacturerer Normally green and blue need the highest voltages the forward...

Page 4: ...all potentiometer on the supply where the output voltage can be adjusted within several percent We recommend to select the lowest voltage where all the LEDs work at full brightness without disturbance...

Page 5: ...e of the LED stripe Regarding any possible voltage drop please see the previous paragraph Cable lengths up to 5 Mtr are allowed Note We found LED stripes of 10 Volts 12 Volts and 24 Volts Note We also...

Page 6: ...perated in a network This means each module can either send or receive data For this the connectors RS232 RX ond RS232 GND are required The precondition for network operation is that all modules of th...

Page 7: ...s Colour transition time 10 seconds Effect 3 Randomly faded colours Blob Effect 4 User defined colour change can be changed by the Chromoflex Editor software for PC default is red green blue Effect 5...

Page 8: ...1 Standard colour change colour transition time 2 5 seconds default On Off Off Effect 2 Slow colour change colour transition time 10 seconds default Off On Off Effect 3 Randomly faded colours Blob On...

Page 9: ...tabele 1 Infrared Remote Control Installation For controlling one ore more modules connected as a network also the infrared control can be used Only one single module within a network should be equip...

Page 10: ...mode is entered At first all modules are stopped so the current colour will remain With buttons 2 and 4 Right and Left the active colour can be set the active colour will blink while button 2 or 4 is...

Page 11: ...n On On Ceiling That s really all to do Software 1 2 3 1 We offer the Chromoflex Editor for free download from our Internet site The software does contain additional documentation not covered by this...

Page 12: ...plies and has considerable advantages compared to traditional systems The modulation frequency is in the range from 120 Hz up to max 240 Hz Patent pending Maximum cable inductance can be calculated as...

Page 13: ...Attachment Module Pinout Chromoflex Manual English V1 07 www barthelme de Rev 02 07 2006 13...