19
Preheat Example: Set a preheat time of 2 hours. Remember: The controller must be at IdLE to begin
programming
Step
Press
Display
Comment
1
Menu
PrHt
If PrHt does not show on the display, even after cycling through the
options, it means that CONE FIRE mode has not been selected. Exit the
menu and select a CONE FIRE speed, then return to the Menu.
2
ENTER
Alternately flashing:
HLd & 00.00
Preheat has been selected; enter the time you want to hold the temperature
at 200
o
F (in this example, 2 hours)
3
2, 0, 0
02.00
Displays the selected time of 2 hours. Numbers to left of decimal point are
hours, to the right are minutes. If you type a wrong number, press zero 4
times, then type the correct number.
4
ENTER
Display returns to current
temperature and IdLE
Accepts the 2 hour preheat time. The current temperature then flashes in
the display.
16-S
( 16 segment program ) Activate the 16-segment option by pressing the Menu key to display “16-S”. Press
ENTER to accept the option. Press “1” until the display shows "On". Press ENTER to complete activation.
In the vary-fire mode, programs 5 and 6 can be combined into a 16-segment program. To combine User 5 and 6, first
program user 5 then program user 6 (each program can have from 1 to 8 segments). Next, recall user 5 then
activate the 16-segment option in the menu. Press Start and the controller will fire user 5 then it will fire user 6.
NOTE: In the vary fire mode, the first segment of user 6 must be an up ramp or the segment will be skipped.
In the cone-fire mode, a cone-fire program is connected to the vary-fire User 6 program. To combine a cone
fire program with User 6, first, program User 6 then program a cone fire. Next, activate the 16-segment option in
the Menu. This is a great way to add multiple cooling segments to a cone fire profile.
Important Note: In the cone-fire mode, the controller uses the first segment of user 6 to transition from the cone
fire program to User 6 so the first segment of User 6 is ignored by the controller. This means that when you
program the number of segments, you must enter 1 greater than the actual number of segments you need. You
then start the actual programming with segment number 2. The controller will ignore any information you enter
into segment 1 so as you program user 6 and the display shows RA 1, press ENTER, ENTER, ENTER to get to
RA 2.
NOTE: 16-S will appear in REVIEW PROGRAM if it is activated.