10/20/20
5
The rain sensor comes with 10
’ leads to connect the rain sensor to the f
our terminals of
the junction box. The white/black twisted pair connect to rain sensor. The red/green twisted
pair connect to the rain sensor power.
Anemometer
For anemometer mounting instructions please refer to WS-201-01B manual.
Temperature Sensor
The thermistor is the temperature sensor. The WeatherBoss junction box has one
thermistor input labeled TH. To ensure proper readings, the thermistor should not be in direct
sunlight or where it will be sprayed with water. The thermistors come with 24’ leads a
nd can be
connected directly to the two terminals labeled TH. There is no special orientation to the
thermistor leads. This in an informational only sensor and cannot be used to control
greenhouse equipment.
Humidity Sensor
The optional humidity sensor should be mounted in any location that it is necessary to
measure humidity levels. The Weather Alarm WR junction box has terminals marked Hum In,
Hum Power and Hum GND. To ensure proper readings, the humidity sensor should not be in
direct sunlight or where it will be sprayed with water. This in an informational only sensor and
cannot be used to control greenhouse equipment.
WeatherBoss Outputs
The WeatherBoss has three alarm outputs
–
wind alarm, rain alarm, and wind or rain
alarm. The wind and rain
outputs activate separately based on individual sensors. The “wind or
rain” output activates when either sensor exceeds its set point.