background image

IMPORTANT SAFETY INFORMATION

2

DANGER! 

Risk Of Fire or Explosion. Flammable Refrigerant Used. 

DO NOT

 Use Mechanical Devices 

To Defrost Ice Maker. 

DO NOT

 Puncture Refrigerant Tubing.

DANGER! 

Risk Of Fire Or Explosion. Flammable Refrigerant Used. To Be Repaired Only By Trained 

Service Personnel. 

DO NOT

 Puncture Refrigerant Tubing.

CAUTION! 

Risk Of Fire Or Explosion. Flammable Refrigerant Used. Consult Repair Manual/Owner’s 

Guide Before Attempting To Install or Service This Product. All Safety Precautions Must be Followed.

CAUTION! 

Risk Of Fire Or Explosion. Dispose Of Property In Accordance With Federal Or Local 

Regulations. Flammable Refrigerant Used.

CAUTION! 

Risk Of Fire Or Explosion. Due To Puncture Of Refrigerant Tubing; follow Handling 

Instructions Carefully. Flammable Refrigerant Used.

The ice maker should be installed in accordance with the safety standard for Refrigeration Systems, 

ASHRAE15. The ice maker shall not be installed in corridors or hallways of public buildings.
If the unit needs to be maintained, replacement components and servicing shall be done by factory 

authorized service personnel, so as to minimize the risk of possible ignition due to incorrect parts or 

improper service.

IMPORTANT: 

The wires in this mains lead are colored in accordance with the following 

code:

GREEN OR GREEN WITH YELLOW STRIP:
WHITE:

BLACK:

To avoid a hazard due to instability of the appliance, it must be placed at an even or flat surface.

GROUNDING

NEUTRAL

LIVE

WARNING! DO NOT

 damage the refrigerant circuit.

WARNING! 

Children should be supervised to ensure that they 

DO NOT

 play with the appliance.

WARNING! 

This appliance must be earthed. And use the 110-120V/60Hz earthed power supply.

SAVE THESE WARNINGS

Summary of Contents for 94023

Page 1: ...LEANING PROCEDURES WRITE THE PRODUCT S SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM OR MONTH AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER OWNER S MANUAL AND SAFETY INSTRUCTIONS I...

Page 2: ...on cord as it may overheat and cause a risk of fire If you must use an extension cord use 16AWG minimum size and rated no less than 1875 watts If the supply cord is damaged it must be replaced by the...

Page 3: ...Carefully Flammable Refrigerant Used The ice maker should be installed in accordance with the safety standard for Refrigeration Systems ASHRAE15 The ice maker shall not be installed in corridors or ha...

Page 4: ...3 RATINGS NOTE TESTED AT 70 F ROOM TEMPERATURE AND 50 F WATER TEMPERATURE SPECIFICATIONS...

Page 5: ...ulate smoothly hot air will blow out when unit running 7 Water draining port Normal plugged with the cap When need to drain the water unplug the cap and connect the white drain pipe 8 Water inlet port...

Page 6: ...ct the inner cabinet is full of ice or not and to check the ice harvest process is over or not D Water tank E Water supplying pipe F Cover board on the right side of the evaporator G Water level switc...

Page 7: ...ice and deice symbol display The machine is making ice when the symbol rotate and the machine is deice when the symbol flash 3 Automatic self cleaning symbol display 4 On off symbol display 5 Error co...

Page 8: ...the refrigerant fluid to settle before plugging the ice maker in if the unit maybe fall upside down during shipping or transportation 5 The appliance must be positioned so that the plug is accessible...

Page 9: ...service engineer This appliance requires a standard 110 120Volt 60Hz electrical outlet with good grounding means RECOMMENDED GROUNDING METHOD For your personal safety this appliance must be properly g...

Page 10: ...ssory again connect the other end of this drainage to the main water drainage pipeline Make sure not to set the drainage pipe too high 3 Connect the water hose to the water faucet of the water main su...

Page 11: ...he ice will be thicker Press button one time the ice making time will reduce one minutes the ice will be thinner Restart the machine it will go back to default 0 NOTE The time currently set only chang...

Page 12: ...ng time and the display content will be switched every 5S WIRING DIAGRAM Your new ice maker may make sounds that are not familiar to you Most of the new sounds are normal The following describes the k...

Page 13: ...fume for cleaning or sanitizing of the ice maker It may cause cracks on the plastic parts Ask a trained service person to check and clean the condenser at least once a year in order to let the unit wo...

Page 14: ...om the water dividing pipe or the water flowing is very small please discharge this water dividing pipe to clean carefully Clean each little holes on the water dividing pipe displayed in the following...

Page 15: ...e as above explanation the water pump runs for 8 minutes and stops for 3 minutes one cycle again one cycle The total duration time is 20 minutes for one self cleaning program During this process the T...

Page 16: ...ump silicone tube water dividing pipe etc should be cleaned by Using Nu Calgon Nickle Safe Ice machine Cleaner per each 6 months They should be cleaned by the serviceman according to ice making assemb...

Page 17: ...16 TROUBLESHOOTING...

Page 18: ...17 PARTS DIAGRAM...

Page 19: ...18 PARTS LIST...

Page 20: ...ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIEDAND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORI...