8. Check the ice production cycle by verifying whether ice cubes are unload to the
storage container.
9. Check the storage container probe for operation: place an ice cube on a cooled
probe inside the storage container; the appliance should stop within 1 minute
and automatically re-start shortly after the ice cube is removed.
10. Re-fix the cover removed beforehand.
Setting Probe in Storage Container
With time, due to the change in ambient temperature, the set value for temperature
probe in the storage container may appear to be insufficient. To set this value,
proceed the following way:
1. In Standby mode, press the control key 3 times over a 2-second period
(Fig. 11).
The control key lights up in white or red.
2. To increase the set temperature, press the control key (Fig. 11) repeatedly and
try to change the key colour to red.
3. To reduce the temperature, press the control key repeatedly until it changes its
colour to white.
If the control key is not pressed during 5 seconds, the entered setting will be saved
and the appliance will leave the change phase.
Operation Status / Alarm Status Indicators
Indicator / Alarm
RED
WHITE
Too long a cooling cycle alarm
blinks 1x
ON 3"
Pump alarm
blinks 1x
blinks 1x
Change in duration of alarm between
two production cycles
blinks 2x
ON 3"
Deposit probe damage alarm
blinks 3x
ON 3"
IR probe alarm
blinks 3x
ON 3"
Discharge/charge parameters
–
HACCP
blinks 3x
blinks 3x
Condenser probe damage alarm
blinks 4x
ON 3"
Evaporator probe damage alarm
blinks 5x
ON 3"
Inverted evaporator
–deposit probe
alarm
blinks 5x
blinks 2x