Installation and operation
16 / 24
1054513
EN
Appliance Connection
1. Connect one end of the included tube with
the gas connection stub at the back of the
appliance.
2. Connect the other end to the gas cylinder or
gas supply connection in the installation
location.
Fig. 6
3. Perform tightness check of all connection points between the gas source and
the appliance. To this end, it is recommended to use suds or spray for detecting
leakages or, possibly, foam producing agents, which do not spur corrosion.
WARNING!
Do not use open fire to test tightness.
4. Apply the selected agent with a brush onto connection points (also on the shut-
off valve)
NOTE!
The connection is tight when there are no bubbles during test.
Resetting to Other Type of Gas / Required Settings
• The appliance is approved and by factory default, prepared to operate with the
type of gas stated on the rating plate (liquid gas).
• If the default factory settings of the appliance are not consistent with the type of
gas available in the installation location, do not connect the appliance to gas
supply.
• To set the appliance to the available gas type, it is necessary to exchange
nozzles and introduce the required settings.
WARNING!
This setting may be introduced by qualified gas installer only, with
consideration for technical data, through exchange of burner nozzles, as
well as through introduction of the resulting settings.
1. The proper data pertaining to the required nozzles are provide in the table of
nozzles (Tab. 2).
Summary of Contents for 1054513
Page 1: ...G 1KB 1K680 1054513 ...