background image

Pag.  8

1.1 IMPORTANT NOTICES

CONTENTS

1. INSTALLATION 

1. INSTALLATION ................................................................................................................................. Pag. 8

1.1 IMPORTANT NOTICES ........................................................................................................................................................ Pag. 8

1.2 POSITIONING ....................................................................................................................................................................... Pag. 9

1.3 EVACUATION OF EXHAUST FUMES .................................................................................................................................. Pag. 9

1.4 CONNECTING GAS ............................................................................................................................................................. Pag. 9

INSTALLATION INSTRUCTIONS ..........................................................................................................................................Pag. 9

CHECK BEFORE INSTALLATION ........................................................................................................................................Pag. 9

CHECKING THERMAL POWER .........................................................................................................................................Pag. 10

CHECKING GAS PRESSURE ....................................................................................................................  

Pag. 10

1.5 CONNECTING TO A DIFFERENT TYPE OF GAS ..............................................................................................................Pag. 11

2.  OPERATING INSTRUCTIONS ....................................................................................................... Pag. 12

2.1 STARTING UP FOR THE FIRST TIME ............................................................................................................................... Pag. 12

2.2 SETTINGS .......................................................................................................................................................................... Pag. 12

3.  CLEANING AND MAINTENANCE ................................................................................................. Pag. 13

3.1 ROUTINE MAINTENANCE ................................................................................................................................................. Pag. 13

3.2 SPECIAL MAINTENANCE .................................................................................................................................................. Pag. 13

3.3 CONTROL AND SAFETY DEVICES ................................................................................................................................... Pag. 13

SPECIFICATIONS TABLE FOR GAS FRY TOPS, CATEGORY II2H3+ ................................................................................... Pag. 13

THE MANUFACTURER RESERVES THE RIGHT TO WITHOUT NOTICE MODIFY THE FEATURES OF THE 

APPLIANCES DESCRIBED IN THIS MANUAL. 

THE MANUFACTURER ACCEPTS NO RESPONSIBILITY FOR HARM CAUSED BY INCORRECT INTERVEN-

TIONS, TAMPERING WITH THE APPLIANCE, MISUSE, POOR MAINTENANCE, NON-COMPLIANCE WITH 

CURRENT REGULATIONS AND INEXPERT USE.

Read this manual carefully because it provides important information on safe installation, use and maintenance of 

the appliance. Keep this manual carefully, so that it can be consulted by different users. If the appliance changes 

owner the user manual must also be transferred to the new owner (if necessary, request a new copy from the 

authorised dealer or directly from the manufacturer).  

•  Only qualified persons must be entrusted with installation operations, adapting the appliance to different types 

of gas, commissioning and eliminating system faults. All current rules and regulations must be complied with. 

•  The appliance must be installed in accordance with the manufacturer’s instructions by professionally qualified 

personnel. .

•  The appliance must be used only by personnel who have been trained in its use. 

•  If the appliance is broken or faulty, disconnect it. If it needs to be repaired, use only an after-sales centre that 

has been approved by the manufacture and ensure that manufacturer approved spare parts are used. 

•  These instructions are valid only for the country whose abbreviations appear on the appliance rating plate.  

•  Non-compliance with the instructions contained in this manual may jeopardise appliance safety.  

The appliance conforms to the Gas Directive 90/396/EEC and has therefore been issued with a CE certificate 

issued by a notified body.  

It meets the following gas regulations:  

-  EN 203 + subsequent updates;

-  EN437 + subsequent updates.

Current installation safety regulations must be complied with.  

Summary of Contents for 131.1413

Page 1: ...N AND MAINTENANCE MANUAL FOR GAS FRY TOPS MANUEL D INSTRUCTIONS POUR L UTILISATION ET L ENTRETIEN DES FRY TOPS GAZ GEBRAUCHS UND WARTUNGSANLEITUNG FÜR GAS FRY TOPS MANUAL DE INSTRUCCIONES PARA EL USO Y EL MANTENIMIENTO DEL FRY TOP GAS REV 04 2012 COD ZSL6508 131 1413 131 1813 ...

Page 2: ...n be consulted by different users If the appliance changes owner the user manual must also be transferred to the new owner if necessary request a new copy from the authorised dealer or directly from the manufacturer Only qualified persons must be entrusted with installation operations adapting the appliance to different types of gas commissioning and eliminating system faults All current rules and...

Page 3: ...t 10 cm away from flammable walls The bain marie may be placed against refractory and non combustible walls Do not obstruct the aspiration or heat di scharge openings and gaps and place the appliance underneath an extraction hood that complies with current standards Fig 1 1 4 CONNECTING GAS INSTALLATION INSTRUCTIONS Installation operations adaptations to other types of gas commissioning and the el...

Page 4: ...juster in order to ensure optimum operation CHECKING THERMAL POWER During initial installation and during maintenance or adaptation to another type of gas nominal heat input must be measured It can be measured by using the volumetric method with the aid of a litre counter or a chronometer After checking connecting pressure and the diameter of the injectors which must be stamped on the injector mea...

Page 5: ... operates correctly instruct the user on how to use it Fig 5 1 5 CONNECTING TO A DIFFERENT TYPE OF GAS REPLACING MAIN BURNER NOZZLE Fig 4 1 Burner 2 Nozzle Before adapting to a new type of gas shut off the gas cock upstream Loosen the screws that hold the front control panel in place and disconnect the electric cables of the piezoelectric ignition Loosen the main injectors Ref 2 and repla ce them ...

Page 6: ...king day switch off the gas check valve upstream of the appliance The control knobs of the burner taps have two positions shut lighting pilot light The appliance must be used only for the purpose for which it was designed Any other use is improper During operation supervise the appliance 2 1 STARTING UP FOR THE FIRST TIME Before starting up the appliance for the first time remove all the packing a...

Page 7: ...arm soapy water on steel surfaces and then rinse in plenty of water and dry with a soft cloth Maintain the shine by regular polishing with a normal liquid polish Do not wash the work top or floor with hydrochloric acid PLATE In order to remove any encrusted residue scrape with a hard plastic spatula positioned at an angle Clean the plate regularly using a damp cloth After cleaning switch the plate...

Reviews: