Installation Instructions
1583011
17 / 32
EN
600 mm between the appliance's surface and horizontal surfaces over the
appliance.
• If keeping the minimum clearance is not possible, walls should be isolated with
non-combustible, thermo-insulation materials (e.g., films made of heat resistant
materials, which may sustain temperature of at least 65°C). Follow fire
protection regulations in force.
• Maintain sufficient lateral clearance for service purposes should maintenance
and repair works be required.
• Before placing the appliance in the intended location, screw the heat-adjustable
feet in designated places at the bottom of the appliance.
• Compensate for smaller unevennesses of flooring in the place of installation
through screwing in and out of the height-adjustable feet.
5.2
Electrical Connection
• Electrical connection of the appliance to mains power supply must be executed
by a qualified electrician, according to international, national and local
regulations in force.
• Before connecting the appliance to mains power supply make sure that the
voltage and frequency values on the rating plate are conforming to the
parameters of local electric installation. The allowable voltage deviation is ±10%.
• The appliance is equipped with a 3x1.5 H07RN-F power cord and mains plug.
• According to international regulations, between the appliance and the mains
power supply there must be a multi-polar circuit breaker furnished, with opening
width of contacts of at least 3 mm per one pole (e.g. a fuse, S type installation
breaker, etc.).
• Unconditionally, the appliance must be grounded.
• The appliance must be connected to a potential equalization circuit (ground).
Connection clamp is located underneath the appliance, near right back leg and
is marked with a symbol of
. The cord's diameter must be 10 mm
2
.
Summary of Contents for 1583011
Page 1: ...Flex 7360 1583011 ...