Manuale d’istruzione per l’installazione, la manutenzione e l’uso
Pentole elettriche
01.08.00 - IT
pagina
25
1.3. CONSTRUCTION
Main structure in AISI 430 with 4 adjustable height feet.
Panels in stainless steel AISI 304, thickness 10-12/10.
Cooking vat in stainless steel AISI 316, thickness 20/10.
Chrome-plated brass drainage tap.
Lid in stainless steel, hinged and spring balanced in all opening positions.
Jacket and lining in stainless steel AISI 304, thickness 15-20/10.
Heating system comprising shielded heating elements made from “Incoloy-800” alloy with boiler and
steam circulation.
Jacket pressure is controlled by a safety valve set at 0.5 bar; the appliance is equipped with an analogue
pressure gauge.
The cold water connection is 10 mm.
The hot water connection is 10 mm.
Safety thermostat to interrupt operation automatically in case of failures.
The appliance is equipped with a three-position selector with three heating functions:
position
“0”
Heating not activated
position
“I”
Reduced power 50%
position
“2”
Full power 100%
Operating thermostat.
1.4. LAWS, TECHNICAL PRESCRIPTIONS AND DIRECTIVES
When installing the appliance it is necessary to follow and comply with the following regulations:
current regulations on the matter;
any hygienic-sanitary regulations concerning cooking environments;
municipal and/or territorial building regulations and fire prevention prescriptions;
current accident prevention guidelines;
electricity board regulations concerning safety;
the regulations of the electrical power supply company or agency;
any other local prescriptions.
1.5. SPECIAL REQUIREMENTS FOR THE INSTALLATION SITE
The room in which the appliance is to operate must be well ventilated.
In addition, it is good policy to locate the appliance under an extractor hood so that cooking vapours can
be removed rapidly and continuously.
Current regulations require the installation of a multiple pole switch between the appliance and the
electrical power supply; the switch must have a contact gap of least 3 mm on each pole.
This appliance requires two water connections: one for hot and one for cold water. Each line must be
fitted with an on-off valve.
Warning! :
The electrical isolating switch and the water shutoff valves must both be located near
to the appliance, within easy reach for the user.