10
ENGLISH
GB
7.
TROUBLESHOOTING
The information below is provided to recognize
and repair any failures that may occur when
operating the appliance.
Some of the failures can be repaired by the user,
others require thorough specialist knowledge.
Such problems may be solved exclusively by the
qualified personnel.
Problem
Cause
Solution
Gas smell.
The smell is sometimes
released when extinguishing
the flame.
Close the gas valve and ventilate the
room.
The ignition flame does not start.
The spark ignition does not
work.
Check operation of ignition devices.
Ignite the flame manually.
Air in the pipes in connection
with the long downtime.
The igniting flame continuously
goes out.
The thermal element is not
sufficiently hot.
Extend the ignition process.
The ignition flame burns, but the
igniter does not ignite the burner.
Check the thermostat. Inspect a
relevant protection device.
When problem persists
contact the service company
Yellow flame.
The burner is contaminated or
moist.
Clean the burner and leave for
drying.
When problem
persists contact the service
company.
It is difficult to rotate the burner
control knob.
Damaged gas valve.
Contact the service company.
The oven does not reach the
preset temperature.
Damaged operational
thermostat.
Replace the part.
Contact the service company.
The safety thermostat tripped.
Wait for the oven to cool down.
Then reset the safety thermostat.