- 35 -
7. Possible Malfunctions
In case of malfunction, disconnect the device from its power source. Before contacting
the service or sales agent, verify - based on the table below - whether it is possible to
eliminate disruption in operation.
Malfunction
Cause
Solution
No cooling
Improperly connected
power cord
Electrical circuit safety fuse
has gone off
Power outage
Damaged temperature
regulator
Pull the plug and reinsert it into
the socket correctly
Check the fuse, check the
device by connecting it to
another socket
Check the power source
Contact the sales agent
Insufficient
cooling capacity
Device is too close to
source heat or direct
sunlight
Poor air circulation in
the device
Improper temperature
setting
Device is overfilled
Ensure sufficient distance
between the device and heat
sources
Ensure sufficient distance from
walls and other objects
Check the settings, set lower
temperature value
Remove excess food products
Device emits
loud sound
Device is placed on an
uneven surface
Device is touching the wall
or other objects
Place the device on an even
surface
Ensure sufficient distance from
the wall and other objects
If you cannot remove the malfunctions:
-
do not open the body,
-
notify the customer service point or contact the sales
agent, while providing the following information:
type of malfunction;
article and serial number
(rating plate at the rear of the device).