- 40 -
WARNING! Danger of burns!
The compressor may be hot when in use.
Do not touch it with bare hands. Use protective gloves!
6.3 Safety instructions for maintenance
o
Check the mains connection cable for damage from time to time. Never operate the
device when the cable is damaged. A damaged cable must immediately be replaced
by customer service or a qualified electrician to avoid dangers.
o
In case of damage or malfunction, please contact your stockist or our customer
service centre. Pay attention to the troubleshooting tips in pt. 7.
o
Only a qualified technician and using original spare parts and accessories should
carry out repairs and maintenance of the device. Do not attempt to repair the
device yourself.
7. Possible Malfunctions
Problem
Cause
Solution
The deep freezer
does not work, the
green standby light
does not come on
•
The plug is not properly
inserted into a socket.
•
The safety fuse is damaged.
•
There is a power failure.
•
Properly insert the plug.
•
Check the power supply.
•
Check the power supply.
The rising
temperature
indicator is red
•
The unit is turned on for the
first time or was left off for a
longer period of time (e.g.
to defrost or following a
power outage).
•
The unit’s door is opened
and closed too often.
•
A large amount of fresh
food products has
caused the temperature
to go above -14
°
C.
Locate the source of the
problem and remove it if
possible.
If the rising temperature
indicator does not go off
after 6 hours, this means
the compressor is working
without interruption or is
not turning on. If this
occurs, contact service or
a sales agent.