background image

 

 

 

- 30 - 

5. Installation and operation 

5.1 Installation 

 CAUTION! 

Installation and maintenance operations may only be performed by qualified 
professionals! 

 
 

Positioning 

 

  Unpack the device and remove the packing materials. 

 CAUTION! 

Never remove the identification plate or warning signs from the device. 

 

  Leave the device on its pallet. 

  Raise the deep freezer using a pallet jack and place it where it is intended to be 

located. 

  Do not push or pull the deep freezer as it may tilt, causing damage to the external 

casing and adjustable legs. 

  When the deep freezer is placed in its intended location, remove the pallet. 

Take care not to hit the device. 

  Place the device in a flat, secure place that will support its weight. 

  Set up the device using the adjustable legs. Use a level as needed. Every leg 

must touch the floor, as otherwise the door may open and close improperly. 

  Remove the protective foil from the device. 

  Not at any time should you place the device on an inflammable surface. 

  Do not place the device in the vicinity of open sources of fire, electric cookers, 

furnaces or other sources of heat such as e.g., in places exposed to direct sunlight. 
The heat can damage the surface of the device, as well as have a negative effect on 
the cooling power and increase the consumption of energy. 

  To avoid damage to the compressor, do not tilt the device to an angle greater than 45° 

during setup or transport. Be careful when touching the condenser and doors, as 
damage to them will negatively impact the working of the device. 

Summary of Contents for 700475

Page 1: ...700475 700495 Original Gebrauchsanleitung V3 1116 ...

Page 2: ...7 2 3 Declaration of conformity 27 3 Transport packaging and storage 28 3 1 Delivery check 28 3 2 Packaging 28 3 3 Storage 28 4 Technical data 28 5 Installation and operation 30 5 1 Installation 30 5 2 Operation 32 6 Cleaning and care 36 7 Possible Malfunctions 38 8 Waste disposal 40 Bartscher GmbH Franz Kleine Str 28 33154 Salzkotten phone 49 0 5258 971 0 Germany fax 49 0 5258 971 120 GB UK ...

Page 3: ... accessible for anyone carrying out the installation servicing maintenance or cleaning Please keep these instructions and give them to future owners of the device 1 Safety This device is designed in accordance with the presently applicable technological standards However the device can pose a danger if handled improperly and inappropriately All persons using the device must follow the recommendati...

Page 4: ...r the care of a person responsible for their safety or have received instructions regarding appropriate use of the device Children should be observed to ensure that they are not playing with the device Only use the device indoors The device is not adapted for use with an external timer or remote control Prevent access of children to the package materials like plastic bags and foamed polystyrene el...

Page 5: ...cable to come into contact with heat sources or sharp edges The power cable should not hang over the side of the working surface Ensure that no one can step on or trip over the cable The power cable must not be folded bent or tangled and must always remain fully unrolled Never place the device or other objects on the power cable Do not lay the power cable over carpets or other inflammable material...

Page 6: ...ate the device with moist hands or standing on wet floor Remove the plug from its socket when the device is not used in case of anomalies during operation before cleaning WARNING Fire or explosion hazard To avoid the hazard results please follow the safety instructions below Do not place any electrical devices such as microwave ovens hair dryer irons boiling pot etc on the top of the deep freezer ...

Page 7: ...on manual All technical activities like installation and maintenance must be performed by the qualified service personnel only The deep freezer is intended only for long term storage of deep frozen products CAUTION Any use going beyond the intended purpose and or any different use of the device is forbidden and is not considered as conventional Any claims against the manufacturer or his authorized...

Page 8: ...d by violation of advice concerning operation and cleaning use other than designed alterations made by user use of inadequate spare parts We reserve the right to make technical changes for purposes of developing and improving the useful properties 2 2 Copyright protection The instruction manual including any texts drawings images or other illustrations is copyright No part of this publication may ...

Page 9: ...r The outer and inner packing material should be removed completely from the device before installation NOTE If you liked to dispose the packing consider the regulations applicable in your country Supply re usable packing materials to the recycling Please inspect the device upon completeness In case any part is missing please contact our customer service center immediately 3 3 Storage Keep the pac...

Page 10: ...djustable feet lockable automatic defrost function water drip evaporation Gross volume 700 litres 1400 litres Coolant R134a Temperature range 18 C to 22 C Ambient temperature up to max 32 C Power 0 69 kW 230 V 50 60 Hz 1 012 kW 230 V 50 60 Hz Dimensions mm W 655 x D 855 x H 2050 W 1320 x D 855 x H 2050 Weight 110 0 kg 191 0 kg Equipment 3 grids 6 grids We reserve the right to make technical change...

Page 11: ... in a flat secure place that will support its weight Set up the device using the adjustable legs Use a level as needed Every leg must touch the floor as otherwise the door may open and close improperly Remove the protective foil from the device Not at any time should you place the device on an inflammable surface Do not place the device in the vicinity of open sources of fire electric cookers furn...

Page 12: ...k hazard The device can cause injuries due to improper installation Before installation and connecting the local power grid specification should be compared with that of the device see rating plate Connect the device only in case of compliance Connect the device only to properly installed single socket with protective terminal Before connecting the device to the power supply for the first time and...

Page 13: ...mperature Indicators Tab 1 Diode Function Normal operating mode Start up ON OFF FLASHING Compressor On OFF Activation ON Ventilator On OFF Activation ON Defrost On OFF Activation ON Auxiliary output Active output Inactive output ON RTC clock RTC available active tEN 1 and at least 1 programmed time cycle RTC unavailable or inactive tEN 0 or no programmed time cycle ON Alarm Alarm active No active ...

Page 14: ...ivation deactivation Pressing together Activation of parameter reset process Pressing for 1 sec Display program version Set mute 1 sec show set desired value Over 3 sec access to other confi gurable parameters enter code 22 disconnect alarm buzzer Pressing for 1 sec RESET EZY Setting desired values To regulate and set desired values press for one second set value will begin flashing to raise or lo...

Page 15: ...to never re freeze thawed or thawing food products Thawed and thawing products should be prepared and consumed within 24 hours Follow producers instructions concerning the freezing of food products It is best to freeze and thaw small portions This ensures quick even freezing and thawing Always write a description of a package s content and date of freezing When freezing larger quantities of food p...

Page 16: ...s have already begun thawing several times over Prevent food products from thawing or beginning to thaw as increased temperatures shorten their storage period and worsen their quality Partially or completely thawed food products should be consumed immediately Low temperatures conserve food products but do not kill microorganisms which quickly recover and cause food products to spoil Partial thawin...

Page 17: ...t could damage the device s surfaces Defrosting Ice that forms inside the device should be defrosted from time to time CAUTION Never damage the coolant circulation Do not use any sharp pointed or other mechanical objects to speed up defrosting For the device completely defrost at least twice per year disconnect it from its power source by removing the plug from its socket and leave the doors open ...

Page 18: ...vice o Wash the external surface with a soft moist cloth If the device is to remain unused for a longer period of time o remove the plug from its socket o remove all food products from the deep freezer o defrost the deep freezer o wash the device s interior and exterior o leave the doors open to allow the deep freezer to dry thoroughly Cleaning the condensor o Clean the condensor at least once a m...

Page 19: ...ducts inside or distance between products is too small Improperly set temperature Remove heat source Ensure sufficient distance between wall and other objects Close door keep open as short a time as possible Contact sales agent Ensure proper distance between products remove unneeded articles Set temperature Deep freezer making unusual or very loud sounds Deep freezer on uneven surface Deep freezer...

Page 20: ... is active temperature value is not displayed and flashes when other alarm signals show or when the measurement value of the second sensor is displayed Contact a sales agent dOr Open door Check multifunction jacks and parameters A4 and A7 Contact a sales agent Ed Last defrost cycle ended as a result of max time being exceeded and not because of normal end of cycle Check parameters dt dP and d4 Che...

Page 21: ...posal service in your community WARNING To exclude any abuse and the dangers involved make the waste device unfit for use before disposal For that purpose disconnect device from mains supply and remove mains connection cable from the device CAUTION For the disposal of the device please consider and act according to the national and local rules and regulations Bartscher GmbH Franz Kleine Str 28 331...

Reviews: