- 38 -
7. Possible Malfunctions
In case of malfunction, disconnect the device from its power source. Before contacting
the service or sales agent, verify - based on the table below - whether it is possible to
eliminate disruption in operation.
Problem
Cause
Solution
No cooling.
•
Plug not in socket.
•
Damaged circuit breaker.
•
Power interruption.
•
Insert plug into socket.
•
Check power source.
•
Check power source.
Insufficient
cooling
•
Direct sunlight or heat source
nearby.
•
Poor air circulation around
deep freezer.
•
Door not closed or held open
for too long.
•
Damaged or misshaped door
seals.
•
Too many products inside or
distance between products is
too small.
•
Improperly set temperature.
•
Remove heat source.
•
Ensure sufficient distance
between wall and other
objects.
•
Close door, keep open as
short a time as possible.
•
Contact sales agent
•
Ensure proper distance
between products, remove
unneeded articles.
•
Set temperature.
Deep freezer
making unusual
or very loud
sounds.
•
Deep freezer on uneven
surface.
•
Deep freezer touches wall or
other object.
•
Door is improperly closed.
•
Place deep freezer on even
surface.
•
Ensure proper distance to
wall and other objects.
•
Close door.
If the problems in operation cannot be eliminated:
-
do not open the body,
-
inform the service or contact the supplier providing:
kind of a problem;
code number and serial number (see identification plate
at the rear wall of the device).