background image

Safety 

 

 

2834431 

3 / 36 

EN 

 

  WARNING! 

The signal word 

WARNING

 warns against hazards that may lead to 

moderate or severe injuries or death if the hazards are not avoided. 

 

 

 

  CAUTION! 

The signal word 

CAUTION

 warns against hazards that may lead to 

light or moderate injuries if the hazards are not avoided. 

 

 

, di e   

IMPORTANT! 

The signal word 

IMPORTANT

 indicates possible property damages, 

which may occur if safety instructions are not observed. 

 

 

NOTE! 

The symbol 

NOTE

 indicates subsequent information and guidelines 

for the user on usage of the appliance. 

 

 

 

 

 

Summary of Contents for 700FX-G396-GCR

Page 1: ...700FX G396 GCR 700FX G796 G 700FX G796 GCR 700FX G796 GR 2834431 2838131 2838231 2838331 DOC NO CR1368860BA EDITION 001 2232...

Page 2: ...cher GmbH Franz Kleine Str 28 D 33154 Salzkotten Germany Phone 49 5258 971 0 Fax 49 5258 971 120 Service hotline 49 5258 971 197 www bartscher com 0085DL0171 Version 1 0 Date of preparation 2022 08 03...

Page 3: ...2 3 Declaration of Conformity 11 3 Transport Packaging and Storage 12 3 1 Delivery Check 12 3 2 Packaging 12 3 3 Storage 12 4 Technical Data 13 4 1 Technical Specifications 13 4 2 Functions of the App...

Page 4: ...s included in this manual is a prerequisite for safe and proper handling of the appliance Additionally accident prevention occupational health and safety and legal regulations in force in the area the...

Page 5: ...ION The signal word CAUTION warns against hazards that may lead to light or moderate injuries if the hazards are not avoided di e IMPORTANT The signal word IMPORTANT indicates possible property damage...

Page 6: ...gas When you sense gas odour observe the following rules immediately close the knob s and the main gas valve provide for sufficient venting of rooms open wide all doors and windows do not light up any...

Page 7: ...when cooking with fats or oils as they may cause fire Close the gas shut off valve should the fire emerge Never put the flame out with water to suppress fire use a lid or a fire blanket Following ext...

Page 8: ...s clean Use only original spare parts Never attempt to repair the appliance on your own Do not introduce any changes in the appliance nor modify it Operating Personnel The appliance may only be operat...

Page 9: ...or is deliberately touching hot substances oil water steam Danger of falling Operator performs actions on the upper part of the device using inappropriate aids e g a ladder with rungs or climbs the de...

Page 10: ...maintenance work if you touch the internal parts of the machine frame Maintenance work may only be performed by qualified personnel equipped with appropriate personal protective equipment cut resista...

Page 11: ...Standard cleaning X Special cleaning X X Maintenance X X Dismantling X Disposal X X Personal protective equipment provided Personal protective equipment is available or must be used if required Perso...

Page 12: ...o be an unintended use The following is an intended use Grilling of meat fish and vegetables 1 6 Unintended Use An unintended use may lead to personal injuries or property damages caused by hazardous...

Page 13: ...ntroduced by the user usage of unapproved spare parts We reserve the right to introduce technical modifications to the product intended for improvement of the appliance and its performance 2 2 Copyrig...

Page 14: ...e used to store the appliance when relocating or when shipping the appliance to our service point in the case of any damages The packaging and its elements are made of recyclable materials Particularl...

Page 15: ...nly in 2838131 2838231 2838331 Safety thermostat only in 2834431 2838231 Material pressure embossed surface with Scotch Brite cut Grease collection container Splash guard The set includes 4 feet May b...

Page 16: ...mperature range min max in C 90 280 Connected load 6 5 kW Dimensions W x D x H in mm 400 x 700 x 295 Weight in kg 44 0 Name Griddle plate 700FX G796 G Art No 2838131 Material CNS 18 10 Roasting surfac...

Page 17: ...e range min max in C 90 280 Connected load 13 kW Dimensions W x D x H in mm 800 x 700 x 295 Weight in kg 72 0 Name Griddle plate 700FX G796 GR Art No 2838331 Material CNS 18 10 Roasting surface materi...

Page 18: ...35 PL I3B P G30 G31 37 25 45 BE FR II2E 3 G20 G25 20 25 17 25 30 G30 G31 28 30 37 20 25 35 45 DE II2ELL3B P G20 20 17 25 G25 20 18 25 G30 G31 50 42 5 57 5 ES GB GR IE IT PT SK II2H3 G20 20 17 25 G30 G...

Page 19: ...ppliance categories Gas pressure mbar Connection pressure mbar Rated Min Max DK SE III1a2H3BP G20 20 17 25 G30 G31 28 30 25 35 G110 8 6 15 IT CH II1a2H G20 20 17 25 G110 8 6 15 NL II2EK3B P G20 20 17...

Page 20: ...RT AT BE BG CH CZ DE DK EE ES FI FR GB GR HR IE IT LT LU LV NO PL PT RO SE SI SK TR G20 G20 G25 20 20 25 UM 185R 185R UP 27 2 27 2 A mm 4 4 Um 130 DE G25 20 UM 200R 200R UP 27 2 27 2 A mm 3 3 Um 130 N...

Page 21: ...HU IE IT LT LU LV MT NL NO PT RO SE SI SK TR G30 G31 28 30 37 28 30 UM 130 130 UP 16 2 16 2 A mm 20 20 Um 85 PL G30 G31 37 UM 120 120 UP 16 2 16 2 A mm 20 20 Um 85 AT CH DE HU G30 G31 50 UM 115 115 UP...

Page 22: ...c valve appliances are equipped with the safety thermostat with manual reset which interrupts heating up when the highest allowable temperature is exceeded To reset the appliance to operational condit...

Page 23: ...4 3 List of Components of the Appliance 2838131 2838231 2838331 2834431 1 Ventilation chimney 2 Splash guard 3 Burner sight glass 4 Grease collection container 5 Piezoelectric igniter 6 Knob 7 Feet 4...

Page 24: ...a fume extraction system In order to provide venting in the place of installation follow indications included in DVGW G631 data sheet Place the appliance in a well ventilated room under a fume extract...

Page 25: ...e so that they may be quickly disconnected if such a need arises The appliance should be placed on surfaces that are even with sufficient bearing capacity resistant to water dry and resistant to high...

Page 26: ...cylinder if it is included is correctly set up and secured and if it is located in a dry place Connect the appliance to the gas supply installation using rigid connection tubes or flexible steel hose...

Page 27: ...iances are set to the following gas type natural gas E Check the type of the supplied gas in the country of installation and if needed reset the appliance to the other gas type Tables 1 and 2 in secti...

Page 28: ...le provided in Table 2 part of the delivery 5 Re tighten main burner s nozzle UM Fig 1 6 Set the air controller Z Fig 2 within the distance of A as provide in Table 2 7 Re tighten firmly the V bolt Fi...

Page 29: ...y flammable materials from the vicinity of the appliance Before starting perform the tightness test using soapsuds Cover connections and pipe fittings with soapsuds Leakages are revealed when bubbles...

Page 30: ...erformed exclusively by the authorized service personnel The user is authorized to perform only everyday routine cleaning to maintain the device in a good condition The appliance should be used solely...

Page 31: ...d its contents are very hot Empty the grease collection container only when it has cooled down Fire hazard Never place any kitchen utensils towels paper etc on the roasting surface during operation Do...

Page 32: ...tely Each time the below description pertains to one heating zone The 2838131 and 2838331 with gas cocks appliances should be started up and if needed set up observing indications in the following sec...

Page 33: ...ic igniter s button 3 Keep the knob 1 pressed for approx 20 seconds and then release it If the ignition flame is out repeat the process The ignition flame may be observed via the sight glass when the...

Page 34: ...ready products from the roasting surface using suitable grilling utensils grill thongs grill fork etc 10 When the grilling process is finished and the appliance is no longer used rotate the knob s to...

Page 35: ...on container and empty it 7 Clean the grease collection container with warm water a mild cleaning agent and a soft cloth or sponge 8 Rinse in fresh water 9 Wipe the housing ventilation chimney and con...

Page 36: ...eter with 0 1 mbar minimum pitch Remove operating panels Remove the retaining screw from the pressure connection Connect the manometer Perform the measurement with an operating appliance Disconnect th...

Page 37: ...ogged line or nozzles Contact the service company Spark plug is incorrectly connected or damaged Connect spark plug or replace it Igniter or spark plug line is damaged Contact the service company Dama...

Page 38: ...act the service company Heating power output control is not possible Damaged knob Contact the service company 9 Disposal At the end of the appliance s operational life cycle dispose of the appliance o...