- 32 -
•
To make dampening and height adjustments, use the adjustable legs as shown in the
above diagram. Large differences in height or tilt can negatively impact the device’s
operation.
•
Before first use, remove the protective foil from the device. Peel the foil off slowly, so
as not to leave any glue. If some glue remains, remove it using an appropriate
solvent.
CAUTION!
The device is not designed to be built-in or for serial installation!
Connecting
Connecting to electricity source
•
Before connecting the device to an electricity source, ensure that the voltage and
frequency values given on the panel correspond to those of the electrical network.
The maximum permissible voltage difference is ± 10%.
•
Check if there is an SL connection fulfilling legal requirements. Use an appropriately
cut cable when connecting the device to electricity.
•
A multipolar breaker must be installed between the device and the electricity supply.
The distance between contacts should be at least 3 mm, and it should be located in
an easily-accessible place.
•
Connect the device to the electricity supply in compliance with all international,
domestic and local regulations.
•
In certain situations, connect the device to a potential equalizing system; follow the
relevant regulations.
Summary of Contents for BETA AC 433V0
Page 2: ......